oneida-air.com 17
24
Connect the Dust Sentry's power adapter (I)
to the small cord next to the Motor Assembly's
(A) magnetic starter [FIG. 24]. The Dust
Sentry's strobe light (I) should be mounted in
a highly visible area using adhesive strips or
the two mounting holes.
Note: Your dust sentry comes with a 110V
power cable, this can be discarded if you're using
the cord pre-installed on your unit.
Assembly Instructions (Continued)
A
FIG. 24
Infrared
Sensor
Vinyl
Hose
Discharge
25
Install the Dust Sentry's (I) infrared sensor (I)
to the pre-cut hole on the Wall Bracket (F).
FIG. 25].
•
Refer to the
Dust Sentry Installation Sheet
for more information.
FIG. 25
Threaded
Inserts
26
Insert 2 Hex Head Bolts (G17) down through
the threaded inserts on the Wall Bracket (F).
Finger tighten only [FIG. 26].
Note: These will protrude down from the Wall
Bracket and help position the 14-gallon bin
directly underneath the cyclone.
FIG. 26
I
Содержание Supercell XSK000014
Страница 2: ......
Страница 31: ...oneida air com 29 Notes...