NCP1060, NCV1060, NCP1063, NCV1063
www.onsemi.com
6
Table 3. MAXIMUM RATING TABLE
(All voltages related to GND terminal)
Rating
Symbol
Value
Unit
Power supply voltage, V
CC
pin, continuous voltage
V
CC
−0.3 to 20
V
Voltage on all pins, except Drain and V
CC
pin
Vinmax
−0.3 to 10
V
Drain voltage
BVdss
−0.3 to 700
V
Maximum Current into V
CC
pin
I
CC
10
mA
Drain Current Peak during Transformer Saturation (T
J
= 150
°
C, Note 2):
NCP1060
NCP1063
Drain Current Peak during Transformer Saturation (T
J
= 125
°
C, Note 2):
NCP1060
NCP1063
Drain Current Peak during Transformer Saturation (T
J
= 25
°
C, Note 2):
NCP1060
NCP1063
I
DS(PK)
300
850
335
950
520
1500
mA
Thermal Resistance Junction−to−Air – PDIP7 with 200 mm
@
of 35−
m
copper area
R
θ
JA
115
°
C/W
Thermal Resistance Junction−to−Air – SOIC10 with 200 mm
@
of 35−
m
copper area
R
θ
JA
132
°
C/W
Thermal Resistance Junction−to−Air – SOIC16 with 200 mm
@
of 35−
m
copper area
R
θ
JA
104
°
C/W
Junction Temperature Range
T
J
−40 to +150
°
C
Storage Temperature Range
T
stg
−60 to +150
°
C
Human Body Model ESD Capability (All pins except HV pin) per JEDEC JESD22−A114F
HBM
2
kV
Charged−Device Model ESD Capability per JEDEC JESD22−C101E
CDM
1
kV
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
1. This device contains latch−up protection and exceeds 100 mA per JEDEC Standard JESD78.
2. Maximum drain current I
DS(PK)
is obtained when the transformer saturates. It should not be mixed with short pulses that can be seen at turn
on. Figure 3 below provides spike limits the device can tolerate.
Figure 3. Spike Limits