18
The direction of rotation of the blade must be anti-clockwise looking at
the slicing machine from the blade guard side. If the direction of rotation
is incorrect, reverse two wires of the three phases of power in the plug
(N.B. do not move the BLUE wire = neutral). It is advisable have this
operation carried out by trained personnel.
The three-phase motors on professional CE slicing machines can operate
with both 230V three-phase voltage and with 400 V voltage.
Unless otherwise specified, connections are made for 400 V power. In
order to adapt to 230 V three phase power, request the intervention of
the “SERVICE CENTRE”.
4.3
WIRING DIAGRAMS
4.3.1
WIRING DIAGRAM OF THE THREE PHASE SYSTEM
Figure 6 - 400 V three phase wiring diagram with 5P plug
Содержание KEA 300 TGI
Страница 1: ...1 Use and maintenance manual AUTOMATIC SLICING MACHINE Edition January 2016 EN...
Страница 4: ...4 CHAPTER 9 TROUBLESHOOTING 31 9 1 TROUBLESHOOTING 31...
Страница 10: ...10 1 3 3 COMPOSITION OF THE MACHINE Normal tray Tray with adjustable rods...
Страница 12: ...12 CHAPTER 2 TECHNICAL DATA 2 1 DIMENSIONS WEIGHT SPECIFICATIONS Figure 2 Overall dimensions...
Страница 19: ...19 4 3 2 WIRING DIAGRAM OF THE SINGLE PHASE SYSTEM Figure 7 230 V single phase wiring diagram with SCHUKO plug...
Страница 33: ...33...
Страница 34: ...34...
Страница 35: ...35...