Settings Required before Application
Section 1-6
16
3. Confirmation
Select both the display unit and either the incident level or the in-
tercepted amount, and then press the ENT Key to confirm the
settings. An example is shown below for measuring the incident
level in millimeters.
For details, refer to
and
1-6-2
Reference Incident Level
When the Sensor Head is mounted for the first time, set the reference inci-
dent level after adjusting the optical axis.
Reset the reference incident level whenever the position of the Sensor
Head is changed.
Adjust the optical axis in RUN Mode so that none of the laser beam is
intercepted, and then press the DOWN Key (
) for 3 seconds or longer.
For details, refer to
3-6-2 Reference Incident Level Setting
and
4-3-3 Setting the Reference Incident Level
ZX-LT005 Sensor Head
Emitter
ZX-LT005 Sensor Head
Receiver
Measurement width: 5 mm
Incident level display
Select 5
−
L, and then
press the ENT Key.
Sensor Head Emitter
Sensor Head Receiver
Press the DOWN Key on the
Amplifier Unit.
Z157-E1-01C.book Page 16 Thursday, August 31, 2006 5:13 PM
Содержание ZX-CAL
Страница 1: ...Smart Sensors ZX Series Operation Manual Cat No Z157 E1 02 OMRON Corporation ...
Страница 20: ...xvi Z157 E1 01C book Page xvi Thursday August 31 2006 5 13 PM ...
Страница 48: ...Outline of Functions Section 2 5 28 Memo Z157 E1 01C book Page 28 Thursday August 31 2006 5 13 PM ...
Страница 160: ...FUN Function Mode Section 4 5 140 Memo Z157 E1 01C book Page 140 Thursday August 31 2006 5 13 PM ...
Страница 166: ...Setting Problems Section 5 2 146 Memo Z157 E1 01C book Page 146 Thursday August 31 2006 5 13 PM ...