Reflective Sensor Heads: FUN Mode Functions
Section 3-5
47
Displaying the Height of the Sensing Object: One-point Scaling B
The height of the sensing object can be displayed by using one-point scal-
ing and inverting the display values.
When the display values are inverted, the larger the displacement, the
smaller the display value. Therefore, the height of the sensing object can
be displayed after inputting the height of a known sensing object.
Because one-point scaling is used, the range of display values is not
changed. The linear output also remains unchanged.
Example:
Example: One-point Scaling B
100.0
80.0
100.0
110.0
70.0
110.0
120.0
60.0
120.0
130.0
50.0
130.0
Sensor Head
X
Y
Although the Y value
must be displayed, the
X value is displayed.
If X = 110 mm
and Y = 70 mm,
Measured value = Display value
Measured value
Display value
: Scaling value input
110 mm is displayed as 70 mm
and
the display values
are inverted.
Display value
(mm)
110.0
70.0
110.0
Actual distance (mm)
Even though the display values
are offset and inverted, the
range of display values remains
unchanged.
Sensing object
All display values are offset
and inverted.
Z157-E1-01C.book Page 47 Thursday, August 31, 2006 5:13 PM
Содержание ZX-CAL
Страница 1: ...Smart Sensors ZX Series Operation Manual Cat No Z157 E1 02 OMRON Corporation ...
Страница 20: ...xvi Z157 E1 01C book Page xvi Thursday August 31 2006 5 13 PM ...
Страница 48: ...Outline of Functions Section 2 5 28 Memo Z157 E1 01C book Page 28 Thursday August 31 2006 5 13 PM ...
Страница 160: ...FUN Function Mode Section 4 5 140 Memo Z157 E1 01C book Page 140 Thursday August 31 2006 5 13 PM ...
Страница 166: ...Setting Problems Section 5 2 146 Memo Z157 E1 01C book Page 146 Thursday August 31 2006 5 13 PM ...