![background image](http://html1.mh-extra.com/html/omron/v400-r1cf/v400-r1cf_user-manual_744093084.webp)
83
V400-R1CF/R1CS
User’s Manual
Section
4
Menu Sheet/Command
L
ist
Section 4
Setting Method
Number of digit output
Whether to output the number of digits to the data output format is specified.
This setting item can be registered as 1 digit of the header and is added to a location
determined by the order of registration.
Two-byte characters are handled as 2 characters in 2D codes.
Set “Clear the header (PR)” to clear the number of digit output.
E.g.: The following describes the steps for setting the number of digit output.
Menu sheet
Command
Number of digit output
(Bar code: 2 digits, 2D code: 6 digits)
_$3_
$3
Number of digit output
(Bar code and 2D code: 6 digits)
_$6_
$6
Setting start (ZZ)
Set the headers collectively (RY)
Output the number of digits ($3)
Setting end (ZZ)
Содержание V400-R1CF
Страница 1: ...Ultra small Multi code Reader Cat No Z276 E1 01 V400 R1CF R1CS USER S MANUAL...
Страница 15: ...14 Introduction Visual Aids V400 R1CF R1CS User s Manual Introduction...
Страница 21: ...20 Section 1 Part Names and Functions V400 R1CF R1CS User s Manual Section 1 Product Overview MEMO...
Страница 43: ...42 Section 2 Installation and Reading V400 R1CF R1CS User s Manual Section 2 Introduction Procedure MEMO...
Страница 53: ...52 Section 3 Communication Data Format V400 R1CF R1CS User s Manual Section 3 Basic Knowledge of Operation MEMO...
Страница 113: ...112 Section 5 Quick Reference Tables of Data Capacities V400 R1CF R1CS User s Manual Section 5 Appendix MEMO...
Страница 116: ...115 V400 R1CF R1CS User s Manual Index Index MEMO...