32
Section
2
Wiring and
Connection
V400-R1CF/R1CS
User’s Manual
Section 2
Introduction Procedure
Example of connection with programmable controller
(CS1)
Connection with programmable controller CS1 (made by OMRON) is explained.
Connect the connection cable of this reader to RS-232C port of the CPU unit.
Wiring
Special cable
V509-W011
Reader
V400-R1CF/R1CS
100 VAC
Dedicated power supply for multi-code reader
S8VS-01505 (made by OMRON)
Power supply unit
C200HW-PA204S
CPU unit
CS1H-CPU67H
Input unit
CS1W-ID21
Programming console
C200H-PRO27
Trigger
switch
Special cable
CS1W-CN224
Pin No.
Wire color Signal name
5
Brown
TRIG
-
Yellow
OK
-
Orange
NG
4
Gray
CS
3
Blue
RS
2
White
RD
1
Green
SD
8
Red
VCC
7
Black
S.GND
Shield
F.GND
Pin No.
Signal name
1
FG
2
SD
3
RD
4
RS
5
CS
6
-
7
-
8
-
9
SG
CS1
RS-232C port
Reader side
Shield
5 VDC (Supplied from the dedicated power supply)
0 V
Содержание V400-R1CF
Страница 1: ...Ultra small Multi code Reader Cat No Z276 E1 01 V400 R1CF R1CS USER S MANUAL...
Страница 15: ...14 Introduction Visual Aids V400 R1CF R1CS User s Manual Introduction...
Страница 21: ...20 Section 1 Part Names and Functions V400 R1CF R1CS User s Manual Section 1 Product Overview MEMO...
Страница 43: ...42 Section 2 Installation and Reading V400 R1CF R1CS User s Manual Section 2 Introduction Procedure MEMO...
Страница 53: ...52 Section 3 Communication Data Format V400 R1CF R1CS User s Manual Section 3 Basic Knowledge of Operation MEMO...
Страница 113: ...112 Section 5 Quick Reference Tables of Data Capacities V400 R1CF R1CS User s Manual Section 5 Appendix MEMO...
Страница 116: ...115 V400 R1CF R1CS User s Manual Index Index MEMO...