SFC Programming Example
Section 1-4
32
the combo box.
Double-click the left-hand side of the action block, and select
D
from the combo
box.
Double-click the timer value and input
3
.
10 Input the transition condition for Step 3.
Right-click the transition after Step 3, and select
Edit Transition Condition
.
Input
gateopenLimit
as the transition condition.
11 Input the name for Step 4.
Right-click Step 4, and select
Edit Step Name
.
Input
CloseGate
into Step 4.
12 Add an action program to the action in Step 4.
Right-click Step 4, and select
Add Action
-
Existing Action
.
Double-click the right-hand side of the action block, and select
A_gateClose
from
the combo box.
13 Input the transition condition for Step 4.
Right-click the transition after Step 4, and select
Edit Transition Condition
.
Input
gatecloseLimit
as the transition condition.
14 Add a jump to Step 1.
Right-click the transition after Step 4, and select
Connections
-
Add Connection
.
On the Add Connection dialog, select
Initial
as the jump destination.
Check the
Draw Connection as Jump
checkbox and click
OK
.
Содержание SYSMAC CX-Programmer 8.1
Страница 1: ...Operation Manual SFC Programming SYSMAC WS02 CXPC1 V8 CX Programmer Ver 8 1 Cat No W469 E1 04...
Страница 2: ...ii CX Programmer Ver 8 1 WS02 CXPC1 V8 Operation Manual SFC Programming Revised February 2009...
Страница 16: ......
Страница 56: ...Precautions When Creating SFC Programs Section 1 5 40...
Страница 117: ...Monitoring Section 4 5 101 For details refer to 3 2 3 Adding an Action to a Step or to the Initial Step...
Страница 118: ...Monitoring Section 4 5 102...
Страница 150: ...Index 134...
Страница 152: ...Revision History 136...
Страница 153: ......
Страница 154: ......