Specifications for Step Control Instructions
Appendix A
121
TSW Instruction
Outline
Changes the present value of the Step Timer.
Symbol
TSW
S
D
S: First word holding the Step Timer’s new present value
D: Step Timer
Description
The present value of the Step Timer specified by S is changed to the value specified starting at D.
Variations
Executed Each Cycle for ON
Condition
TSW
Variations
Executed Once for Upward
Differentiation
@TSW
Immediate Refreshing Specification
None
Applicable Program Areas
Area
Function
block
definitions
Block
program
areas
Step
program
areas
Subroutines Interrupt
task
programs
Usage
OK OK
OK OK
OK
Operand Specifications
Area
S
D
CIO Area (e.g., I/O bits)
CIO 0000 to CIO
6142
Work Area
W000 to W510
Holding Bit Area
H000 to H510
Step Timer
Auxiliary Bit Area
A448 to A958
DM Area
D00000 to D32766
EM Area
E00000 to E32766
En_00000 to
En_32766
(n = 0 to C)
Constants
&0 to &65535
Condition Flags
Name
Label
Status
Error Flag
P_ER
OFF
Note:
•
Specify Step Timers in the form
step_name
.T. Refer to
2-3-1 Steps
for details.
•
Refer to
2-3-1 Steps
for information on using this instruction.
•
This instruction cannot be input or displayed on a Programming Console. “?” will be displayed.
Содержание SYSMAC CX-Programmer 8.1
Страница 1: ...Operation Manual SFC Programming SYSMAC WS02 CXPC1 V8 CX Programmer Ver 8 1 Cat No W469 E1 04...
Страница 2: ...ii CX Programmer Ver 8 1 WS02 CXPC1 V8 Operation Manual SFC Programming Revised February 2009...
Страница 16: ......
Страница 56: ...Precautions When Creating SFC Programs Section 1 5 40...
Страница 117: ...Monitoring Section 4 5 101 For details refer to 3 2 3 Adding an Action to a Step or to the Initial Step...
Страница 118: ...Monitoring Section 4 5 102...
Страница 150: ...Index 134...
Страница 152: ...Revision History 136...
Страница 153: ......
Страница 154: ......