8 Message Communications
8-36
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
04 hex
Interface Counters
The path to the link object in the
physical layer
Read
Struct
---
In Octets
The number of octets received
through the interface.
This includes unnecessary multi-
cast packets and discarded pack-
ets counted by InDiscards.
UDINT
Reads the current value.
In Unicast Packets
The number of unicast packets
received through the interface.
This does not include discarded
packets counted by InDiscards.
UDINT
Reads the current value.
In NonUnicast Packets
The number of packets besides
unicast packets received through
the interface. This includes
unnecessary multicast packets,
but does not include discarded
packets counted by InDiscards.
UDINT
Reads the current value.
In Discards
The number of discarded incom-
ing packets received through the
interface.
UDINT
Reads the current value.
In Errors
The number of incoming packets
that had errors. This is not
included in InDiscards.
UDINT
Reads the current value.
In Unknown Protos
The number of incoming packets
that were of an unknown protocol.
UDINT
Reads the current value.
Out Octets
The number of octets sent
through the interface.
UDINT
Reads the current value.
Out Unicast Packets
The number of unicast packets
sent through the interface.
UDINT
Reads the current value.
Out NonUnicast Packets
The number of packets besides
unicast packets sent through the
interface.
Read
UDINT
Reads the current value.
Out Discards
The number of discarded sent
packets.
UDINT
Reads the current value.
Out Errors
The number of sent packets that
had errors.
UDINT
Reads the current value.
Attribute ID
Parameter name
Description
Attribute
Read/write data
Data
type
Value
Содержание SYSMAC CJ1W-EIP21
Страница 8: ...Manual Structure 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 10: ...Sections in this Manual 8 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 20: ...Read and Understand this Manual 18 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 42: ...Revision History 40 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 68: ...1 Introduction 1 26 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 80: ...2 Installing Ethernet Networks 2 12 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 130: ...6 Testing Communications 6 4 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 206: ...7 Tag Data Link Functions 7 76 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 246: ...8 Message Communications 8 40 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 266: ...9 FTP Server 9 20 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 374: ...13 Troubleshooting 13 56 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 431: ...Index 1 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 I Index...
Страница 436: ...Index 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 Index...
Страница 437: ......