7-43
7 Tag Data Link Functions
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
7
-2
Se
tti
n
g T
a
g D
a
ta
Li
n
k
s
7
7-2
-7 Creating Connections b
y
De
vice Dr
agg
ing an
d Dropp
ing
5
Click the
Next
Button to switch to the table in the following Wizard Dialog Box. Follow the
instructions to select and input from the list box the input tag set of the originator device that
receives the output tag set of the target device.
•
The blank area in the Input Tag Set Column is the connection that you are creating.
•
The rows in which there are input tag sets are connections that are already set.
•
To prevent duplicate settings, input tag sets that have been used are not displayed in the list
box for input tag sets.
•
If there is no applicable input tag set, you can edit a tag set or create a new one by using the
Edit Tag Sets
Button and
Edit Tag
Button.
6
Once the input tag set settings have been completed, click the
Finish
Button. You can check the
set connection by selecting Network - View Devices Connection Structure Tree from the
menus.
•
The Wizard can be ended even if the input tag set includes a blank row. In that case, a connec-
tion is not created for the blank row.
•
You can delete a connection by deleting the input tag sets that were previously set.
You can create a connection to the originator by dragging a target device and dropping it at the origina-
tor device. Network Configurator version 3.10 or higher is required to drag and drop devices to make
connections.
Example:
Drag the target device at 192.168.250.1 and drop it at the originator device at
192.168.250.100.
7-2-7
Creating Connections by Device Dragging and Dropping
Drag & Drop
Содержание SYSMAC CJ1W-EIP21
Страница 8: ...Manual Structure 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 10: ...Sections in this Manual 8 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 20: ...Read and Understand this Manual 18 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 42: ...Revision History 40 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 68: ...1 Introduction 1 26 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 80: ...2 Installing Ethernet Networks 2 12 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 130: ...6 Testing Communications 6 4 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 206: ...7 Tag Data Link Functions 7 76 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 246: ...8 Message Communications 8 40 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 266: ...9 FTP Server 9 20 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 374: ...13 Troubleshooting 13 56 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Страница 431: ...Index 1 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 I Index...
Страница 436: ...Index 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 Index...
Страница 437: ......