![Omron SYSDRIVE 3G3JV-A4002 Скачать руководство пользователя страница 123](http://html1.mh-extra.com/html/omron/sysdrive-3g3jv-a4002/sysdrive-3g3jv-a4002_user-manual_742832123.webp)
7-7
n72
RS-422A/485 Parity Selection
Register
0148 Hex
Changes during
operation
No
Setting
range
0 to 2
Unit of
setting
1
Default setting
0
Set Values
Value
Description
0
Even
1
Odd
2
No parity
In normal serial communications, data is configured in single bytes, and messages are created by
stringing together multiple bytes of data. The parity check described here sets the check for each byte of
data. Set the parity check method that is required by the Master.
Note
The entire message is checked by a separate check code called “CRC-16,” so the communica-
tions data will be checked even if no special parity check is performed.
H
Send Wait Time Setting (n73)
•
Set this parameter to an awaiting period for returning a response after the DSR (data-send-request)
message is received from the Master.
n73
RS-422A/485 Send Wait Time
Register
0149 Hex
Changes during
operation
No
Setting
range
10 to 65 (ms)
Unit of
setting
1 ms
Default setting
10
Set Values
•
When the DSR message is received from the Master, the Inverter must wait for a communications time
of 24-bit length plus the set value in n73 before returning a response.
Set this value according to the response time of the Master.
H
RTS Control Selection (n74)
•
Select whether or not to enable the RTS (request-to-send) communications control function.
•
This function can be disabled (i.e., set to “1”) only when a 1-to-1 Master/Slave configuration is used in
RS-422A communications. When multiple Slaves are used for RS-422A, or whenever RS-485 com-
munications are used, it is necessary to set “0” (enable RTS control).
n74
RS-422A/485 RTS Control
Selection
Register
014A Hex
Changes during
operation
No
Setting
range
0, 1
Unit of
setting
1
Default setting
0
Set Values
Value
Description
0
Enabled
1
Disabled (Available to 1-to-1 RS-422A communication only)
Communications
Chapter 7
Содержание SYSDRIVE 3G3JV-A4002
Страница 1: ...USER S MANUAL SYSDRIVE 3G3JV Compact Simplified Inverters Cat No I528 E1 04...
Страница 3: ...USER S MANUAL Compact Simplified Inverter SYSDRIVE 3G3JVSERIES...
Страница 16: ......
Страница 20: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Страница 26: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 57: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Страница 65: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 190: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Specifications of Accessories 9 3 Option Specifications 9...
Страница 216: ...Chapter 10 List of Parameters 10...
Страница 229: ...Chapter 11 Using the Inverter for a Motor 11...