No.13S080-10
72
STC-CMB200PCL / STC-CMC200PCL / STC-CMB401PCL / STC-CMC401PCL
Specifications and Users guide
Command No.
Command Description
A0H:
VAHA[7..0]
A1H:
VAHA[15..8]
[Vertical ROI Effective Line ROI_A]
STC-CMB200PCL/CMC200PCL: Initial data: VAHA [15..0] = 1,088, data range: 0 to 1,088
STC-CMB401PCL/CMC4401PCL: Initial data: VAHA [15..0] = 2,048, data range: 0 to 2,048
Sets the number of the effective lines (image height) of the variable partial scanning.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
grater than below value:
STC-CMB200PCL/CMC200PCL:
1,088, STC-CMB401PCL/CMC4401PCL:
2,048
A2H:
VAHB[7..0]
A3H:
VAHB[15..8]
[Vertical ROI Effective Line ROI_B]
STC-CMB200PCL/CMC200PCL: Initial data: VAHB [15..0] = 1,088, data range: 0 to 1,088
STC-CMB401PCL/CMC4401PCL: Initial data: VAHB[15..0] = 2,048, data range: 0 to 2,048
Sets the number of the effective lines (image height) of the variable partial scanning.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
grater than below value:
STC-CMB200PCL/CMC200PCL:
1,088, STC-CMB401PCL/CMC4401PCL:
2,048
A4H:
VAHC[7..0]
A5H:
VAHC[15..8]
[Vertical ROI Effective Line ROI_C]
STC-CMB200PCL/CMC200PCL: Initial data: VAHC [15..0] = 1,088, data range: 0 to 1,088
STC-CMB401PCL/CMC4401PCL: Initial data: VAHC[15..0] = 2,048, data range: 0 to 2,048
Sets the number of the effective lines (image height) of the variable partial scanning.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
grater than below value:
STC-CMB200PCL/CMC200PCL:
1,088, STC-CMB401PCL/CMC4401PCL:
2,048
A6H:
VAHD[7..0]
A7H:
VAHD[15..8]
[Vertical ROI Effective Line ROI_D]
STC-CMB200PCL/CMC200PCL: Initial data: VAHD [15..0] = 1,088, data range: 0 to 1,088
STC-CMB401PCL/CMC4401PCL: Initial data: VAHD[15..0] = 2,048, data range: 0 to 2,048
Sets the number of the effective lines (image height) of the variable partial scanning.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
grater than below value:
STC-CMB200PCL/CMC200PCL:
1,088, STC-CMB401PCL/CMC4401PCL:
2,048
A8H:
VAHE[7..0]
A9H:
VAHE[15..8]
[Vertical ROI Effective Line ROI_E]
STC-CMB200PCL/CMC200PCL: Initial data: VAHE [15..0] = 1,088, data range: 0 to 1,088
STC-CMB401PCL/CMC4401PCL: Initial data: VAHE[15..0] = 2,048, data range: 0 to 2,048
Sets the number of the effective lines (image height) of the variable partial scanning.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
grater than below value:
STC-CMB200PCL/CMC200PCL:
1,088, STC-CMB401PCL/CMC4401PCL:
2,048
AAH:
VAHF[7..0]
ABH:
VAHF[15..8]
[Vertical ROI Effective Line ROI_F]
STC-CMB200PCL/CMC200PCL: Initial data: VAHF [15..0] = 1,088, data range: 0 to 1,088
STC-CMB401PCL/CMC4401PCL: Initial data: VAHF[15..0] = 2,048, data range: 0 to 2,048
Sets the number of the effective lines (image height) of the variable partial scanning.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
grater than below value:
STC-CMB200PCL/CMC200PCL:
1,088, STC-CMB401PCL/CMC4401PCL:
2,048
For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *[email protected] *http://www.aegiselect.com
Aegis
Electronic
Group,
Inc.