No.13S080-10
70
STC-CMB200PCL / STC-CMC200PCL / STC-CMB401PCL / STC-CMC401PCL
Specifications and Users guide
Command
No.
Command Description
78H:
TESTP[7..0]
[Test Pattern] Initial data: TESTP [7..0] = 00H
Sets the test pattern video output.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
0: Normal Video Image
1: Gray Scale
2: Ramp
3: 100% White
4: White Clip
6: Color Bar
Others: Black
79H:
EFFCT[7..0]
[Image effect selection] Initial data: EFFCT[7..0] = 00H
Sets the image effect.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7:
Negative / Positive video selection
0: Positive image
1: Negative image
D6 to D0:
Image effect
00H: No effect (Original)
01H: 9bit gradation
02H: 9bit gradation
03H: 7bit gradation
04H: 6bit gradation
05H: 5bit gradation
06H: 4bit gradation
07H: 3bit gradation
08H: 2bit gradation
09H: 1bit gradation
0A to 7FH: No Function
(Prohibited settings. Do not set these values)
80H:
E2P[7..0]
[EEPROM control] Initial data: E2P[7..0] = 00H
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D1:
No function
Always
set as “0000000”
D6 to D0:
Write control to the EEPROM
0: Prohibited
1: Accept
Note: This bit is cleared to “0” automatically by the internal processes after the execution of the command.
81H:
INI[7..0]
[Reload camera default setting] Initial data: INI [7..0] = 00H
Sets the factory setting.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D0:
Factory Setting
0: No Function
170: Reload factory
setting
Note: Once reloaded the camera setting, this register may set “0” automatically