SGE/SCC
18
Edge Controller
(1) Handle with care
Do not drop the product or expose it to excessive vibration or
mechanical shock. The product may be damaged and may not
function properly.
(2) Adhesion of solvent
Do not allow organic solvents, such as alcohol, thinner,
trichloroethane, or gasoline, to come into contact with the product.
Such solvents make the markings on the Edge Controller illegible
and cause deterioration of parts.
(3) Storage and operating conditions
Do not store or use the products under the following conditions.
1. In direct sunlight
2. At ambient temperatures not between -20 and 55°C
3. At relative humidity not exceeding 90% or under temperature
changes that could causes condensation
4. At air pressure out of the range of 86 to 106 kPa
5. In corrosive or combustible gases
6. Where subject to vibration or mechanical shock beyond the
rated values
7. Where subject to contact with water, oil, or chemicals
8. In an atmosphere containing excessive dust, saline, or metal
powder
(4) Wiring
1. Use the following to wire to the Edge Controller.
• Stranded wire (Flexible wire): 0.75 to 1.5 mm
2
• Solid wire: 0.75 to 1.5 mm
2
• Strip the cover of wire no longer than 7 mm.
• Terminal tightening torque: 0.5 to 0.6 N·m
2. Ground the negative side of the power supply. A controller
with the positive side grounding will not work.
(5) Mounting of multiple Edge Controllers
Place the safety edges farther than 25 mm from the nearest SCC.
(6) Mounting of the Edge Controller to DIN rails
Use end plates (PFP-M: sold separately) on both ends of SCC.
(7) This is a Class A product (Product in industrial setting). Use of the
product in residential setting may cause radio disturbance. In such
case, take appropriate measures.
Safety Edge
(1) Make sure to use the Safety Edge SGE series in combination with
the Edge Controller SCC series or Safety controller G9SP series.
(2) Handle with care
1. Do not drop the product or expose it to excessive vibration or
mechanical shock. The product may be damaged and may
not function properly.
2. Do not apply loads on a certain location of the Safety Edge for
a long period of time. It may damage the Safety Edge.
3. Do not use the Safety Edge submerged in water or in
locations continuously subject to splashes of water.
(3) Adhesion of solvent
Do not allow organic solvents, such as alcohol, thinner,
trichloroethane, or gasoline, to come into contact with the product.
Such solvents make the markings on the Edge Controller illegible
and cause deterioration of parts.
(4) Storage and operating conditions
Do not store or use the products under the following conditions.
1. In direct sunlight
2. At ambient temperatures not between -25 and 75°C
3. At air pressure out of the range of 86 to 106 kPa
4. In corrosive or combustible gases
5. Where subject to vibration or mechanical shock beyond the
rated values
6. Where subject to contact with water, oil, or chemicals
7. In an atmosphere containing excessive dust, saline, or metal
powder
(5) Mounting of the Safety Edge
1. Use dedicated mounting brackets to install the Safety Edge.
2. Do not install the Safety Edge on an environment with a
projection. Install it on a flat surface.
3. Do not pull the cables to lift or move the Safety Edge.
4. Do not use the Safety Edge with a cover on it.
(6) This is a Class A product (Product in industrial setting). Use of the
product in residential setting may cause radio disturbance. In such
case, take appropriate measures.
Safety Category
The Safety Edge is certified for PLe and Safety Category 3 when used
with an SCC-series Edge Controller. The Safety Edge is certified for
PLd and Safety Category 3 when used with a G9SP-series Safety
Controller.
To implement a Safety Category 3 and PLd safety circuit with an
external safety relay or magnet contactor connected, a safety
controller is required separately when using the Safety Edge with an
SCC-series Edge Controller.
Standards
SGE-
@
EN1760-2
EN ISO13849-1
SCC-
@
EN ISO13849-1 PLe/Safety Category 3