SGE/SCC
5
Step 2. Wiring Configuration and Cable Termination
Determine a wiring configuration according to the number of safety edges (sensor) in series. (Up to 5 safety edges can be connected in series.)
There are five types of cable termination for both ends of the safety edge. The method can be selected from the combinations of 2-wire cable,
cable with M8 connector (male or female), and terminating resistor as shown below.
Note: 1.
To connect safety edges in series, two types of methods are available : Using a 2-wire cable or M8 connector.
2.
To connect with an edge controller, a 2-wire cable should be used. There is no polarity.
*
Use of a terminating resistor is required on one side of the last series-connected safety edge.
Configuration Example
Using one safety edge (Configuration No. 2 x 1)
Using two safety edges
Connecting using 2-wire cables
(Config. No. 0 x 1) + (Config. No. 2 x 1)
Connecting using connectors
(Config. No. 5 x 1) + (Config. No. 4 x 1)
Using N safety edges
Connecting using 2-wire cables
(Config. No. 0 x (N - 1)) + (Config. No. 2 x 1)
Connecting using connectors
(Config. No. 5 x 1) + (Config. No. 3 x (N-2)) + (Config. No. 4 x 1)
Configuration
No.
Outline drawing
Wiring configuration and cable termination
0
2-wire cable on both sides
2
2-wire cable on one side, terminating resistor on the other side
(8.2k
Ω
0.25W)
*
3
Connector cable on one side (male), connector cable on the
other side (female)
4
Connector cable on one side (male), terminating resistor on the
other side (8.2k
Ω
0.25W)
*
5
2-wire cable on one side, connector cable on the other side
(female)
2-
w
ire ca
b
le 2-
w
ire ca
b
le
Safety edge
2-
w
ire ca
b
le
Terminating resistor
Safety edge
Connector ca
b
le (male)
Connector ca
b
le (female)
Safety edge
Connector cable (male)
Terminating resistor
Safety edge
2-
w
ire ca
b
le
Connector ca
b
le (female)
Safety edge
SCC Edge Controller
Safety Edge
Confi
g
. No. 2
Connected
Terminating resistor
Safety Edge
Confi
g
. No. 0
Confi
g
. No. 2
Safety Edge
Connected
SCC Edge Controller
Terminating resistor
Connected
Safety Edge
Confi
g
. No. 5
Confi
g
. No. 4
Safety Edge
Connector ca
b
le (male)
Connector ca
b
le (female)
Connected
SCC Edge Controller
Terminating resistor
Safety Edge
Confi
g
. No. 0
Confi
g
. No. 0
Safety Edge
Connected
Confi
g
. No. 0
Safety Edge
Connected
Confi
g
. No. 2
Safety Edge
Connected
SCC Edge Controller
Terminating resistor
Safety Edge
Confi
g
. No. 5
Confi
g
. No. 3
Safety Edge
Confi
g
. No. 3
Safety Edge
Confi
g
. No. 4
Safety Edge
Connector ca
b
le
(male)
Connector ca
b
le
(male)
Connector ca
b
le
(male)
Connector ca
b
le
(female)
Connector ca
b
le
(female)
Connector ca
b
le
(female)
Connected
SCC Edge Controller
Terminating resistor