SGE/SCC
6
Step 3. Sensor Length
Determine the length of a safety edge.
Choose any length from
mm
*
to
mm with increments of 50 mm.
*
When the length is less than 1,000 mm, zero "0" is added on the top of the number to make it four digits.
Note: 1.
The user cannot cut the safety edge.
2.
For other lengths, contact your OMRON representative.
Step 4. Mounting Base
Aluminum base is used to mount a safety edge (sensor) to equipment. Select one from the following.
Note:
A base with more than 1.2 m is cut and split before delivery as shown below.
(Example) When the sensor length LEN is 2,700 mm, three 900 mm mounting bases will be provided.
Step 5. Cable Length and Cable Termination
Determine the cable length of both ends of the safety edge.
Choose
mm length or any length from
mm
to
mm with increments of 500 mm.
Note: 1.
For internal terminal registor side, there is no cable. Cable
length is not specified.
2.
Code length is indicated by five digits. Add 00 on the top the
number for 100 mm or more and less than 1,000 mm, add 0
for 1,000 mm or more and less than 10,000 mm.
3.
For other lengths, contact your OMRON representative.
Determine the cable termination method for both ends of a safety
edge and add a code at the end of the cable length.
Note:
When using a terminating resistor, cable termination method is
not required to be selected.
Step 6. Direction of Cable Connection
Determine the direction of the cable that is connected to the Safety Edge.
Note:
Refer to “
Model Number Legend”
for 5 and 6 in the above table.
Orders can be customized by selecting items from Step 1 to 6.
Also see
"Model Number Legend"
on the following page.
Model
SGE-125
SGE-225/245
SGE-365
Code
None
None
L
None
L
Shape
Sensor length = LEN (mm)
Mounting base cut length (mm)
No. of split bases
0150 to 1200
LEN
1
1210 to 2400
1/2 LEN
2
2410 to 3600
1/3 LEN
3
3610 to 4800
1/4 LEN
4
4810 to 6000
1/5 LEN
5
6010 to 6100
1/6 LEN
6
0150
6100
3.3
15
9
14
13
25
14
16
25
13
35
15
14
15
14
17.6
35
Code
Specification
C
2-wire cable
M
Connector cable (male)
F
Connector cable (female)
00100
00500
10000
Code
Direction of Cable Connection
SGE-125
SGE-225
SGE-245(L)
SGE-365
None
The cables are connected
to the right side of the
Safety Edge.
The cables are connected
to the bottom of the Safety
Edge.
R
―
The cables are connected
to the right side of the
Safety Edge.
L
The cables are connected
to the left side of the
Safety Edge.
The cables are connected
to the left side of the
Safety Edge.
5
6
5
6
6
5
5
6
5
6