Error Message Tables
Section 5-3
5-3
Error Message Tables
When a Project Is Newly
Created
During System Setup
5-4
Precautions When Replacing the PT
If a fault is discovered in the inspection and the PT must be replaced, observe
the following precautions.
• Before replacing the PT, back up all of the PT’s project data. If the PT is
repaired by OMRON, the project data may be deleted.
• Before replacing the PT, be sure to turn OFF the power supply.
• After replacing the PT, check to be sure that there are no errors in the new
PT.
If the PT is to be returned to OMRON for repair, attach a document to the PT
describing the problem in as much detail as possible, and send the PT to an
OMRON representative listed at the end of the manual.
Error message
Contents
Countermeasure
The combination of
the selected PT
model and system
version is invalid.
An attempt was made to
select a version not supported
by NSH5-SQ
@
-V2.
Select a version to match the
PT.
Error message
Contents
Countermeasure
There is an error in
the communications
address input format.
An illegal address or other
than a bit address has been
set for the key status monitor
address (emergency stop,
function switches F3, F4, F5,
F8, F9, F10).
Check the key status monitor
address and correct the
address that was set.
An illegal address or other
than a word address has been
set for the station status moni-
tor address.
Check the station status moni-
tor address and correct the
address that was set.
$SB cannot be spec-
ified.
$SB was specified for the sta-
tion status monitor address.
Set an address other than
$SB.
$SW cannot be
specified.
$SW was specified for the sta-
tion status monitor address.
Set an address other than
$SW.
Specify a PT mem-
ory address.
An address not in the PT
memory was specified for the
station status monitor
address.
Check the station status moni-
tor address and set an
address in the PT memory.
The combination of
the selected PT
model and system
version is invalid.
An attempt was made to con-
vert a project that is being
edited to a PT model that is
not supported.
Select a version that matches
the PT model.
Содержание NSH5
Страница 2: ......
Страница 4: ...iv ...
Страница 12: ...xii ...
Страница 16: ...xvi ...
Страница 24: ...xxiv EC Directives 6 ...
Страница 58: ...34 Installing the Mounting Bracket Section 2 5 ...
Страница 86: ...62 Connection Method Section 4 5 ...
Страница 92: ...68 Precautions When Replacing the PT Section 5 4 ...
Страница 98: ...74 General Specifications Appendix A ...
Страница 99: ...75 Appendix B Dimensions 75 50 176 223 75 Four M4 70 5 16 5 ...
Страница 102: ...78 Types of Memory Appendix C ...
Страница 107: ...83 Recommended Enabling Circuits Appendix D Program Example ...
Страница 108: ...84 Recommended Enabling Circuits Appendix D ...