OMRON
NS Series Quick Start Manual
Page 31
(1) First you can type some comments in "Comment" box.
(2) Action type can be changed, select "Momentary".
(3) Then choose the second Button type from the list [Rectangle(Type2)]. There are
many other types like ready made shapes and custom shapes.
(4) Now you can specify the "Write Address" and "Display Address1". Click on the Set
button of the "Write Address". The "Address Setting" window will appear. You can
choose Host Name from registered hosts list. When selecting PT Memory, the
acceptable memory area can be "Internal Memory ($B)" or "System memory ($SB)".
When selecting SerialA or other Host, the memory area type can be any supported by
the Host PLC.
Note
If you didn't select any communications in the System Setting window, there are no
Hosts in the Host Name list. This programming example will use only the internal
memory, not any PLC-communications.
(5) Select the PT Memory as the Host Name.
(6) Select the Internal Memory as the Area Type.
(7) Then type or click the address in Number section, e.g. 10. Note that when the
Internal Memory $B is selected, there is no need to set Word and Bit addresses
separately because the memory area type is already bit memory. Only the Word
address can be set but it means just one memory bit because $B area includes
32768 bits. Refer to the chapter 3-3-1.
5
6
7
Then click on the [OK] button.
(8) Set the address in the Display Address (e.g. $B20) as previously shown or write
the address directly to the address field. This address controls the color of the button.
(9) The color of the OFF and ON state can be set in the "Color/Shape" tab.
8