75
SECTION 18
Appendix
18-1 Appendix A
Checkout procedure log
The following checkout procedure must be performed by qualified personnel
during initial MS2800 system installation and at least every three months or
more frequently depending on machine usage and company guidelines.
Machine identification____________________________ Date____________
Technician Signature ___________________________________________
Item
Condition
Comments
Verify that the guarded machine is compatible with
the type of machine which may be used with the
MS2800 system. See the chapter - "Precautions on
Safety" for further information.
@
Pass
@
Fail
Verify that the mounting distance of the MS2800 sys-
tem is equal to or greater than the minimum safe dis-
tance from the danger point. See the chapter "Safe
mounting distance" for further information.
@
Pass
@
Fail
Determine that all access to the danger point not pro-
tected by the MS2800 system is guarded by other
means, such as gates, fencing or other approved
methods. Verify that all additional guarding devices
are installed and operating properly.
@
Pass
@
Fail
Make sure the operator is not able to stand between
the MS2800 system detection zone and the machine
danger point. Verify that the light curtain can only be
reset from a position outside and within view of the
hazardous machine area.
@
Pass
@
Fail
Inspect the electrical connections between the
guarded machine's control system and the MS2800
system. Verify that they are properly connected to
the machine such that a stop signal from the
MS2800 system results in an immediate halt of the
machine's cycle. See the chapter "Connecting to the
machine control circuit" for further information.
@
Pass
@
Fail
If the EDM monitoring feature is not used, proceed to
the next step. To test the EDM feature, verify that the
feature has been enabled. Turn the machine power
on. Cycle the machine. Place a temporary jumper
wire between the EDM connections. The MS2800
should enter an alarm condition. Remove the tempo-
rary jumper. Press and release the start button.
@
Pass
@
Fail
Record the test results in the machine log, then per-
form the test procedure.
@
Pass
@
Fail
Содержание MS2800E
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 19: ...2 Section ...
Страница 25: ...8 MS2800FS Cascaded Series Section 4 3 ...
Страница 33: ...16 Optical Synchronization Section 5 4 ...
Страница 39: ...22 Selecting Scan Codes Section 7 7 ...
Страница 41: ...24 Auxiliary Output Section 8 2 ...
Страница 51: ...34 General Mounting Considerations Section 10 3 ...
Страница 57: ...40 Using the test object Section 13 3 ...
Страница 59: ...42 Section ...
Страница 85: ...68 Accessories Section 15 9 ...
Страница 87: ...70 Section ...
Страница 91: ...74 Receiver Error Codes Section 17 5 ...
Страница 95: ...78 ...