38
Muting Controller RM-6
Section 12-1
The MS2800 system requires a specific sequence to activate the muting func-
tion after the RM-6 is connected. Once the RM-6 is connected the system will
not operate until either the mute module is removed or the following sequence
is followed:
• The MS2800 will fault "71", (mute module enable and configuration
required)
• With the power OFF, the start button must be pressed and remain
pressed while the power is applied
• The three LEDs on the receiver end-cap will start flashing after 3 seconds
• The start button must be released within 5 seconds after the LEDs start
flashing
When this sequence is properly completed, the system will enable muting.
For further information please check the user manual of the RM-6.
Содержание MS2800E
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 19: ...2 Section ...
Страница 25: ...8 MS2800FS Cascaded Series Section 4 3 ...
Страница 33: ...16 Optical Synchronization Section 5 4 ...
Страница 39: ...22 Selecting Scan Codes Section 7 7 ...
Страница 41: ...24 Auxiliary Output Section 8 2 ...
Страница 51: ...34 General Mounting Considerations Section 10 3 ...
Страница 57: ...40 Using the test object Section 13 3 ...
Страница 59: ...42 Section ...
Страница 85: ...68 Accessories Section 15 9 ...
Страница 87: ...70 Section ...
Страница 91: ...74 Receiver Error Codes Section 17 5 ...
Страница 95: ...78 ...