20
Operating mode selection
Section 7-2
7-1-2
Receiver selector switch settings
7-2
Operating mode selection
The operating mode is selected by setting position 1 of switches A and B,
located on the receiver. Any mismatch between the settings of switches A and
B will result in an alarm condition. The available operating modes are auto-
matic start and Start/Restart Interlock.
7-3
Selecting and programming Fixed Blanking
Refer to section
for details on selecting and programming
Fixed Blanking function.
7-4
Selecting and programming Floating Blanking
Floating Blanking is activated by setting position 4 of Switches A and B
located on the receiver.
Note
When Floating Blanking is active, the amber LED will illuminate to indicate
that the system is operating in a less sensitive state.
7-5
Selecting External Device Monitoring (EDM)
EDM is activated by setting position 2 of Switches A and B located on the
receiver. Any mismatch between the settings of Switches A and B will result in
an alarm condition.
7-6
Selecting Machine Test Signal (MTS)
MTS is activated by setting position 2 located on the transmitter end cap.
Switch A Position
Function
Switch B Position
Function
Factory Default
1
Auto Start or Start/
Restart Interlock
1
Auto Start or Start/
Restart Interlock
Auto Start (OFF)
2
EDM
2
EDM
Disabled (OFF)
3
Scan Code
3
Scan Code
Scan Code A (OFF)
4
Floating Blanking 1
4
Floating Blanking 1
Disabled (OFF)
5
Fixed Blanking
5
Fixed Blanking
Disabled (OFF)
6
Program (Non-safety)
6
Range (Non-safety)
Program (toggle)
Long Range (ON)
RECEIVER SELECTOR SWITCHES
(Shown in factory default positions)
SW A
Auto/SRI
EDM
Fixed BK
Scan Code
FB1
Program
Auto/SRI
EDM
Fixed BK
Scan Code
FB1
Range
SW B
SW A
SW B
Operating Mode
Automatic Start
1 = Off
1 = Off
Start/Restart Int
1 = On
1 = On
EDM
Disabled
2 = Off
2 = Off
EDM
Enabled
2 = On
2 = On
Scan Code
A
3 = Off
3 = Off
Scan Code
B
3 = On
3 = On
FB1
Disabled
4 = Off
4 = Off
FB1
Enabled
4 = On
4 = On
Fixed Blanking
Disabled
5 = Off
5 = Off
Enabled
5 = On
5 = On
Program
6 = Toggle
Operating Range
Short Range
6 = Off
Long Range
6 = On
3
2
1
5
4
6
3
2
1
5
4
6
ON
ON
Содержание MS2800E
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 19: ...2 Section ...
Страница 25: ...8 MS2800FS Cascaded Series Section 4 3 ...
Страница 33: ...16 Optical Synchronization Section 5 4 ...
Страница 39: ...22 Selecting Scan Codes Section 7 7 ...
Страница 41: ...24 Auxiliary Output Section 8 2 ...
Страница 51: ...34 General Mounting Considerations Section 10 3 ...
Страница 57: ...40 Using the test object Section 13 3 ...
Страница 59: ...42 Section ...
Страница 85: ...68 Accessories Section 15 9 ...
Страница 87: ...70 Section ...
Страница 91: ...74 Receiver Error Codes Section 17 5 ...
Страница 95: ...78 ...