6
OMRON Scientific Technologies Inc.
© OMRON STI 0613 PN99804-0060 Rev. B
20
6 U
SING
S
ELECTOR
S
WITCHES
T
O
S
ET
F
EATURES
6
6 . 1 M
AN UA L
S
E L E CT O R
S
W I T CH
VE RS IO N
The operating parameters of the MS4800S Series light curtains are configured via selector switches.
See below.
6 . 2 A
C CE SS
T O
T HE
S
E L E C T O R
S
W I T CH ES
The switches are located behind a flip door on both the transmitter and receiver. The flip up doors are
opened by loosening two retaining screws. (see illustration below)
Figure 6-1 MS4800S Selector switches
6.2.1
T
RA NSMITTER
S
EL ECTOR
S
WITCH
S
ETTINGS
NOTE! MTS is not available/applicable on the 5-pin version of the MS4800, the MTS selector
switches MUST remain in the OFF position.
Table 6-1 Transmitter Selector Switch Settings
Figure 6-2 Transmitter Selector Switches
Switch Position
Function
Factory Default
1
SCAN CODE
SCAN CODE A
2
MTS
MTS OFF
ENDCAP WITH DOOR
SELECTOR SWITCH ACCESS
RCVR
XMTR
RECEIVER SELECTOR SWITCHES
TRANSMITTER SELECTOR SWITCHES
SELECTOR SWITCH ACCESS
3
2
1
5
4
6
1
2
3
2
1
5
4
6
ON
ON
ON
Scan Code
Frequency A 1 = Off
Frequency B 1 = On
MTS
(Must be set to Off position)
Disabled 2 = Off
Enabled 2 = On
ON
MTS
Scan Code
TRANSMITTER SELECTOR SWITCHES
(Shown in factory default positions)
1