OMRON Scientific Technologies Inc.
21
© OMRON STI 0613 PN99804-0060 Rev. B
6.2.2
R
ECEIVER
S
ELE CTOR
S
WITCH
S
ETTINGS
Table 6-2 Receiver Selector Switch Settings
Note: 1. Program and Range are non-safety signals and are not redundant
NOTE! EDM is not available/applicable on the 5-pin version of the MS4800, the EDM selector
switches MUST remain in the OFF position.
Figure 6-3 Receiver Selector Switch Settings
6 . 3 O
P E R AT I NG
M
OD E
S
EL E C T IO N
The Operating mode is selected by setting position 1 of Switches A and B, located on the receiver.
Refer to Figure 6-3
Receiver Selector Switch Settings
. Any mismatch between the settings of switches
A and B will result in an alarm condition. The available operating modes are Automatic Start and
Start/Restart Interlock. The 5-pin version should only be used in Automatic Starte Mode.
6 . 4 S
EL E C T IN G
A ND
P
RO G RAM M IN G
F
IX E D
B
L A NK IN G
Refer to section 4.1.1
Selecting Fixed Blanking with Selector Switches
for programming instructions.
NOTE! When Fixed Blanking is active, the amber LED will illuminate to indicate that the system is
operating in a less sensitive state.
6 . 5 S
EL E C T IN G
F
L OA T I NG
B
L A NK IN G
Floating Blanking is activated by setting position 4 of Switches A and B located on the receiver. Refer
to Table 6-2
Receiver Selector Switch Settings
.
NOTE! When Floating Blanking is active, the amber LED will illuminate to indicate that the
system is operating in a less sensitive state.
6 . 6 S
EL E C T IN G
S
C AN
C
O DE S
The MS4800S receiver and transmitter offer scan code selection to minimize cross-talk. On the
transmitter this is activated by setting position 1. On the receiver this is activated by setting position 3
of switch A and switch B.
NOTE: Both receiver and transmitter must be set to the same code.
Switch A
Position
Function
Switch B
Position
Function
Factory Default
1
Auto Start or Start/Restart Interlock
1
Auto Start or Start/Restart Interlock
Auto Start (Off)
2
EDM (Always Disabled)
2
EDM (Always Disabled)
Disabled (Off)
3
Scan Code
3
Scan Code
Scan Code A (Off)
4
Floating Blanking 1
4
Floating Blanking 1
Disabled (Off)
5
Fixed Blanking
5
Fixed Blanking
Disable (Off)
6
Program (Non-safety)
6
Range (Non-safety)
Program (toggle)
Short Range (Off)
RECEIVER SELECTOR SWITCHES
(Shown in factory default positions)
SW A
Auto/SRI
EDM
Fixed BK
Scan Code
FB1
Program
Auto/SRI
EDM
Fixed BK
Scan Code
FB1
Range
SW B
SW A
SW B
Operating Mode
Automatic Start
1 = Off
1 = Off
Start/Restart Int
1 = On
1 = On
EDM
Disabled
2 = Off
2 = Off
EDM
Enabled
2 = On
2 = On
Scan Code
A
3 = Off
3 = Off
Scan Code
B
3 = On
3 = On
FB1
Disabled
4 = Off
4 = Off
FB1
Enabled
4 = On
4 = On
Fixed Blanking
Disabled
5 = Off
5 = Off
Enabled
5 = On
5 = On
Program
6 = Toggle
Opera
Short Range
6 = Off
Long Range
6 = On
3
2
1
5
4
6
3
2
1
5
4
6
ON
ON
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]