Figure 9-4 Correct Mounting Example with Proper Alignment
This example shows the minimum distance from the reflective surface, d, to one side of the beam
center line.
Figure 9-5 Minimum Distance from a Reflective Surface as a Function of Range
9 . 2 C
RO SS
T
AL K
M
IT I G AT I ON
To mitigate interference from other light curtains, the MS4800 has two possible scan codes, A and B.
The transmitter and receiver units must be set to the same scan code for the receiver to enter the
MACHINE RUN state.
Transmitter
Receiver
Approach direction
Central beam
Light beam interrupted
d
Reflective Surface
Perimeter of danger area
Reflection
Interruption
a
Beam Angle, a
0
100
300
500
700
900
2m
4m
6m
8m
10m
12m
14m
16m
Minimum distance
Range (m)
18m
20m
1.1m
1.3m
0.3m
d(mm)