1 4
OMRON SCIENTIFIC TECHNOLOGIES INC.
Fremont CA USA
Tel: 1/888/510-4357 in USA and Canada
© OSTI 1209 PN99584-0050 Rev. E
Original Instructions
50
Minimum Object Resolution:
• 12 mm minimum object resolution systems:
— With no Floating Blanking: 12.0 mm (0.47 inches)
1
— With 1-beam Floating Blanking: 19 mm (0.75 inches)
1
— With 2-beam Floating Blanking: 26 mm (1.02 inches)
1
• 14 mm minimum object resolution systems:
— With no Floating Blanking: 14.0 mm (0.55 inches)
1
— With 1-beam Floating Blanking: 25 mm (0.98 inches)
1
— With 2-beam Floating Blanking: 36 mm (1.42 inches)
1
• 20 mm minimum object resolution systems:
— With no Floating Blanking: 20.0 mm (0.79 inches)
1
— With 1-beam Floating Blanking: 31 mm (1.22 inches)
1
— With 2-beam Floating Blanking: 42 mm (1.65 inches)
1
• 30 mm minimum object resolution systems:
— With no Floating Blanking: 30.0 mm (1.18 inches)
1
— With 1-beam Floating Blanking: 52 mm (2.05 inches)
1
— With 2-beam Floating Blanking: 74 mm (2.91 inches)
1
1
Use of Exact Channel will increase this value
Floating Blanking
OFF
Floating Blanking
1 Channel
Floating Blanking
2 Channels
MCJ-12
25 mm
31 mm
37 mm
MCJ-20
29 mm
40 mm
50 mm
MCJ-30
32 mm
52 mm
73 mm
MCJ4700 Joint Resolution (Resolution at the corner)
Safety Output:
Din & Solid State Output version of Metal Chassis Controllers: Two PNP each output
sourcing 625 mA @ 24 VDC.
Relay version of metal chassis controller only: 1 N.O. and 1 N.C. /N.O. rated for 6A at 230 VAC.
Auxiliary (non-safety) Output:
Din & Solid State Output version of Metal Chassis Controllers: One NPN output sinking 100 mA @
24 VDC. One PNP sourcing 250 mA @ 24 VDC.
Relay version of metal chassis controller only: 1 N.O./N.C. rated at 3A @ 230 VAC.
MPCE
: 50mA @ 24 VDC
Maximum Response Time:
for details of response time by
protected height.
Power Input:
Din & Solid State Output version of Metal Chassis Controllers: 24 VDC ± 20%, 2A*, . Power
supply must meet the requirements of IEC 60204-1 and IEC 61496-1. OMRON STI part number
42992 or equivalent.