3
OMRON SCIENTIFIC TECHNOLOGIES INC.
Fremont CA USA
Tel: 1/888/510-4357 in USA and Canada
© OSTI 1209 PN99584-0050 Rev. E
Original Instructions
12
3.1.2
LCM M
ETAL
C
HASSIS
C
ONTROLLER
Switches for configuring system features are located inside the front cover of the controller. Access to
these switches is gained by the unlocking the clasp on the right-hand side of the controller box.
The Clasp has provisions to accept a user-provided padlock. Only a qualified p erson should have
possession of the key to the padlock, or to the optional Program/Start keyswitch.
STO P
R U N
RUN
S TA R T
IN TERLO CK
FB/ CS
W A R N I N G
Scientific Technologies Inc, Fremont, CA 94555 U. S. A.
R
!
T o test the light curtain, use the appropriate ST I -
supplied test object, or properly sized opaque cylindrical
object.
I f you are using the C hannel S elect or F loating
B lanking features and the object to be ignored does not
completely prevent access to the hazardous area, either
(1) use a mechanical guard or other means to block
access or (2) increase the minimum safe distance and
use a larger test object diameter as explained in the
I nstallation and Operating Manual.
1. Disable the machine. Power on the light curtain.
2. I nspect the machine to ensure entry to the
hazardous area is only through the light curtain sensing
field. I f not, additional guarding, including mechanical
barriers may be required.
3. Verify that the mounting distance of the light
curtain is equal to or greater than the minimum safe
distance from the hazardous point. E nsure the operator
is not able to stand undetected between the light curtain
and the hazard.
4. C heck for external damage to the light curtain,
the machine, electrical cables and wiring.
5. I nterrupt the sensing field with the test
object to check the effectiveness of the light curtain.
M ove the test object inside the perimeter (along the top,
Do Not Remove Or Cover This Label
http:/ / www.sti.com
1/ 888/ 510-4357
S T I L abel P /N 28621-0010 re
T
ES T
P
R O C ED U R E
sides and bottom) of the sensing field and up and down
through the center of the sensing field. Verify that the
R ed indicator is ON and the Green indicator is OFF while
the test object is anywhere in the sensing field.
watch for any unprotected access to the point of hazard.
6. Start the machine. I nterrupt the sensing field
wi th the test obj ect. T he machi ne shoul d stop
i mmedi atel y. N ever i nsert the test object i nto the
dangerous parts of the machine! With the machine at
rest, interrupt the sensing field with the test object.
that the machine will not start with the test object in the
sensing field.
7. E nsure the braking and machine stop systems
are working properly in accordance with the machine
manufacturerÕs requirements. I f the machine does not
stop fast enough, adjust the braking system or increase
the distance from the light curtain to the point hazard.
8. I f the safety devices or machine fail any of these
tests, do not run the machine. I mmediately lockout the
machine to prevent its use and notify the supervisor
9. I f the C hannel S elect is reprogrammed or
disabled, you must repeat these test procedures.
10. C lose and lock the light curtain contr
enclosure door, if applicable.
D ia g n o s tic Co d e s :
00
N ormal O peration
01
N ormal O peration, waiting for Start signal
02
N ormal O peration, Floating Blanking active
03
N ormal O peration, Exact Channel Select active
04
N ormal O peration, Exact Channel Select and
Floating Blanking active
20
G eneral DIP switch fault
21
Invalid switch setting
22
DIP switch settings changed during operation
23
Invalid Channel Select or MPCE switch settings
30
G eneral Safety O utput fault
40
G eneral MPCE fault
41
MPCE open before safety output (O SSD) activation
43
MPCE open when power is applied
50
Internal controller fault
51
Receiver fault
52
Transmitter fault
53
Transmitter and receiver length mismatch or transmitter
and receiver not connected
59
24 VDC power supply fault
Clasp
P R O G R A M
Optional
Keyswitch
Figure 3-2 Accessing the Configuration Switches on the LCM-Metal Chassis Controller