WARNING!
DeviceNet is not a safety rated system and is only used to provide status information. Never use
information provided by DeviceNet to control a machine.
C.1 I
NTRODUCTION
The 4700 systems are available which allow communication of non-safety, monitoring and diagnostic
information across the DeviceNet BUS.
C.2 F
EATURES
— Connects to network using simple removable terminal blocks
—The following information is available to DeviceNet:
C.2.1
S
YSTEM
IDENTIFICATION
— Manufacturer, Product Name, Product Serial Number
C.2.2
S
YSTEM
STATUS
— Operating Mode
— Detection zone
— Safety Outputs
— Signal Strength
— Number of Beams Installed
— Number of Beams Selected
C.2.3
S
YSTEM
S
ETTINGS
— Operating Mode/Automatic Start/Start interlock
— MPCE Monitoring Enabled/Disabled
— 1-Beam Floating Blanking Active/Inactive
— 2- Beam Floating Blanking Active/Inactive
— Exact Channel Select Active/Inactive
— Blanking pattern for Exact Channel Select