1 4
OMRON SCIENTIFIC TECHNOLOGIES INC.
Fremont CA USA
Tel: 1/888/510-4357 in USA and Canada
© OSTI 1209 PN99584-0050 Rev. E
Original Instructions
54
• Response Time for MCF4700, MCJ4700 and MSF4700
The MCF and MCJ can have up to four segments. It is possible for each segment to have a different
minimum object resolution.
Step 1: Determine the number of beams in each segment using
.**
Step 2: Use the formula below to determine response time:
(Total number of beams x 0.0924) + 5.21 msec = response time in msec.
**The total number of beams in a system cannot exceed 192.
MCF4700 example:
MCF47-12200-301800-20300
The unit has three segments, a 12 mm resolution of 200 mm length, a 30 mm resolution of 1800 length
and a 20 mm resolution of 300 mm length.
show 32 beams for the 12 mm segment,
show 84 beams for the 30 mm segment
shows 28 beams for the 20 mm segment. The total number of beams is:
32 + 84 + 28 = 144.
From the formula: