KP100G
41
LCD(Data Logger) Messages
Operating
conditions
In English
In German
In Spanish
In Italian
Description
Normal Working Status
Shown in “Status” row on the display
Power off
PV inverter is totally shutdown,
BUS voltage < 200V
Standby STATUS:STANDBY
Status:Bereitschaft
ESTADO:EN ESPERA
IN ATTESA
IPV <200V & 600V< BUS
voltage
Initialization &
waiting
STATUS:Waiting Status:Warten
ESTADO:PREPARADO PRONTO
Input voltage range 260~350V
during start-up.
Check grid
STATUS:CHECKING
xxxs
Status:Netz-Prüf xxxs
ESTADO:CHEQUEO
xxxs
VERIFICA RETE xxxs
When PV voltage> 350V,
inverter is checking feeding
conditions
Feeding grid,
MPPT
STAUS:Normal Status:Normalbetriebe
ESTADO:NORMAL
NORMALE
Inverter is feeding power. After
10 seconds of this display, LED
will show wattage.
Waiting for
reconnect to grid
STATUS:RECONNECT
xxxs
Status:Kontakt xxxs
ESTADO:RECONEX
xxxs
RICONNESSIONE xxxs The time for reconnect to grid
FAULT
STATUS:FAULT
Status:Fehler
ESTADO:ANOMALIA
SISTEMA IN ERRORE
See “System Fault”,
“Inverter Fault” to know
the fault detail
Monitoring Parameters
Information on display
Instantaneous Input
power
Pdc:xxxx/xxxx/xxxxW Pdc:xxxx/xxxx/xxxxW Pdc:xxxx/xxxx/xxxxW
Pcc:xxxx/xxxx/xxxxW
The individual DC input power
Instantaneous
Output power
Pac:xxxxxW Pac:xxxxxW Pac:xxxxxW Pca:xxxxxW
The real time output power in
xxxx W
Accumulated
energy information
Etot:xxxxxxxxx.xkWh E-tot:xxxxxxxxx.xkWh Etot:xxxxxxxxx.xkWh Etot:xxxxxxxxx.xkWh
Total energy to has been fed to
grid since inverter was installed
3-phase Grid
voltage
Vac:xxx.x/xxx.x/xxx.xV Uac:xxx.x/xxx.x/xxx.xV Vac:xxx.x/xxx.x/xxx.xV
Vca:xxx.x/xxx.x/xxx.xV
Grid voltage in xxx.x VAC for
3 phases
Grid frequency
Frequency:xx.xHz
Frequenz:xx.x Hz
Frecuencia:xx.x Hz
Frequenza:xx.x Hz
Grid frequency in xx.x Hz
Feeding current
Iac:xx.x/xx.x/xx.xA
Iac:xx.x/xx.x/xx.xA Iac:xx.x/xx.x/xx.xA Ica:xx.x/xx.x/xx.xA
Feeding current amount in xx.x
A
PV array voltage
Vdc:xxx/xxx/xxxV
Udc:xxx/xxx/xxxV Vdc:xxx/xxx/xxxV Vcc:xxx/xxx/xxxV
Input voltage of PV array, xxx
VDC
PV array current
Idc:xx.x/xx.x/xx.xA
Idc:xx.x/xx.x/xx.xA Idc:xx.x/xx.x/xx.xA Icc:xx.x/xx.x/xx.xA Input DC current of tracker
Daily Energy
Etoday:xxx.xkWh
E-Heute:xxx.xkWh
Edia:xxx.xkWh
Egiorno:xxx.xkWh
The accumulated kWh of that
day
Working Hour
H-total:xxxxxxhr
H-total:xxxxxxhr
Htot:xxxxxx
Ore tot:xxxxxx
Total working hours of inverter
Internal
Temperature
TEMPERATURE:xx.xºC Temperatur:xx.xºC
Temperatura:xx.xºC
Temperatura:xx.x°C
Temperature is indicated in
Celsius
Содержание KP100G
Страница 1: ...KP100G Technical manual Grid Connect Photovoltaic Inverter Part number 1868180 8 A...
Страница 50: ...KP100G 50 EC DECLARATION OF CONFORMITY...
Страница 51: ...KP100G 51 Technical Report...
Страница 52: ...KP100G 52 Declaration of Conformity RD1663 2000...
Страница 53: ...KP100G 53 Declaration of Conformity DK5940...