![Omron K3NP Скачать руководство пользователя страница 94](http://html1.mh-extra.com/html/omron/k3np/k3np_operation-manual_743364094.webp)
86
It is possible to reset the process value by pressing the RESET/TEACH Key.
5-3-4 HOLD
·
The K3NP will stop the measurement if the HOLD input is ON.
·
When the HOLD input is ON, the K3NP will retain the process value, output,
and BCD data effective immediately before the HOLD input.
·
The HOLD indicator is lit while HOLD input is ON.
·
If the HOLD input is turned ON while the measurement is being performed, the
measurement will be cancelled and the previous measurement value (dis-
played value) will be retained.
·
No measurement will be started while the HOLD input is ON.
Process value
External Input Signals
Section 5-3
Содержание K3NP