218
Analog Input Functions
Section 7-9
7-9-4
Related Areas and Settings
System Setup
Tab page
Function
Settings
Time when setting
becomes effective
Analog Input/
Output
Both inputs
and outputs
Input
method
0 hex:
END refresh
1 hex:
Immediate refresh (Refresh with PRV(881).)
At power ON and
start of operation
Output
method
0 hex:
END refresh
(Content of A560 and A561 is output as
analog output after execution of END
instruction.)
1 hex:
Immediate refresh
(Analog output when SPED(885) or
ACC(888) is executed. A560 and A561
used for monitoring.)
At power ON and
start of operation
Inputs
Input range
00 hex:
−
10 to 10 V
01 hex: 0 to 10 V
02 hex: 1 to 5 V (4 to 20 mA)
03 hex: 0 to 5 V
At power ON
Outputs
Output
range
00 hex:
−
10 to 10 V
01 hex: 0 to 10 V
02 hex: 1 to 5 V
03 hex: 0 to 5 V
5A hex: Disable outputs (See note.)
Note
Outputs can be disabled to shorten the I/O
refreshing time or reduce the Motion Control
Module’s power consumption.
At power ON
Output stop
function
0 hex:
Clear outputs
1 hex:
Hold outputs
2 hex:
Maximum value
Outputs
Output
range
These parameters have the same settings as output
1, above.
Output stop
function
Содержание HOME SECURITY SYSTEM - MOTION SENSOR FQM1-CM001
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x TABLE OF CONTENTS...
Страница 11: ...xii...
Страница 23: ...xxiv Data Backup 5...
Страница 53: ...30 Function Tables Arranged by Purpose Section 1 7...
Страница 71: ...48 Memory Block Diagram Section 2 7...
Страница 254: ...231 Analog Outputs Section 7 10...
Страница 255: ...232 Analog Outputs Section 7 10...
Страница 263: ...240 Connecting the CX Programmer Section 8 2...
Страница 285: ...262 Inspections Section 10 1...
Страница 397: ...374 Auxiliary Area Allocations Appendix D...
Страница 409: ...386 Index...
Страница 411: ...388...