2.3 Details ofServices
H8GN
2-11
This service reads the run status of the controller.
MRC SRC
Response
code
0 6 0 1
2
2
4
MRC SRC
0 6 0 1
2
2
Run
status
Related
informaĆ
tion
2
2
Service request PDU
Service response PDU
(1) Run status
Run status
Description
00
Status in which the count (timer) input can be accepted (error not
generated when setup area is 0)
01
Status in which the count (timer) input cannot be accepted (other
than above)
(2) Related information
0
0
7
0
6
5
4
3
1
2
Bit position
PV underflow
0
0
0
0
0
(3) Response code
At normal completion
Response code
Name
Description
0000
Normal completion
No errors were found.
At occurrence of error
Response code
Name
Description
1001
Command too long
The command is too long.
2203
Operation error
CPU or EEPROM error
JRead controller