3.1 Variable Area (setup range) List
H8GN
3-3
Variable
type
Address
Item
Set (monitor) Value
Level
C2
0000
Set value
H'00000000 to H'0000270F (0 to 9999)
* Input mode at counter=incremental or decreĆ
mental
Operation
H'FFFFFC19 to H'0000270F (-999 to 9999)
* Input mode at counter=individual or phase difĆ
ferent input
H'00000000 to H'0000270F (0 to 9999)
* Time range at timer=other than Ć ĆmĆ Ćs,
Ć ĆhĆ Ćm and output mode=A,B,D,E,F
H'00000000 to H'000026E7 (0:00 to 99:59)
* Time range at timer=Ć ĆmĆ Ćs, Ć ĆhĆ Ćm and
output mode=A,B,D,E,F * Note 2
H'00000000 to H'00000064 (0 to 100)
* Output mode at timer=Z
C2
0001
Set value 0
H'00000000 to H'0000270F (0 to 9999)
* Input mode at counter=incremental or decreĆ
mental
Adjustment
H'FFFFFC19 to H'0000270F (-999 to 9999)
* Input mode at counter=individual or phase difĆ
ferent input
H'00000000 to H'0000270F (0 to 9999)
* Time range at timer=other than Ć ĆmĆ Ćs,
Ć ĆhĆ Ćm and output mode=A,B,D,E,F
H'00000000 to H'000026E7 (0:00 to 99:59)
* Time range at timer=Ć ĆmĆ Ćs, Ć ĆhĆ Ćm and
output mode=A,B,D,E,F * Note 2
H'00000000 to H'00000064 (0 to 100)
* Output mode at timer=Z
C2
0002
Set value 1
Same as set value 0
C2
0003
Set value 2
Same as set value 0
C2
0004
Set value 3
Same as set value 0
C2
0005
Cycle time
H'00000000 to H'0000270F (0 to 9999)
* Time range at timer=other than Ć ĆmĆ Ćs,
Ć ĆhĆ Ćm
Operation
H'00000000 to H'000026E7 (0:00 to 99:59)
* Time range at timer=Ć ĆmĆ Ćs, Ć ĆhĆ Ćm * Note 2
* Note 1: This item is not displayed on the controller display.
* Note 2: Even if the set value is within the setting range, the outĆofĆrange error occurs when the 2nd digit (sextal number) is six
or above such as 5:60 (H*00000230).