3.1 Variable Area (setup range) List
H8GN
3-5
Variable
type
Address
Item
Set (monitor) Value
Level
C3
0009
Decimal point
H'00000000(0): Ć Ć Ć Ć
H'00000001(1): Ć Ć Ć.Ć
H'00000002(2): Ć Ć.Ć Ć
H'00000003(3): Ć.Ć Ć Ć
Initial setting
C3
000A
PreĆscale value
H'00000001 to H'0000270F (0.001 to 9.999)
C3
000B
Input signal edge
H'00000000(0): Rise edge
H'00000001(1): Fall edge
C3
000C
Communications unit
No. *1
H'00000000 to H'00000063 (0 to 99)
CommunicaĆ
tions setting
C3
000D
Baud rate *1
H'00000000(0): 1.2
H'00000001(1): 2.4
H'00000002(2): 4.8
H'00000003(3): 9.6
C3
000E
Communications data
length *1
H'00000007(7): 7
H'00000008(8): 8
C3
000F
Communications stop
bit *1
H'00000001(1): 1
H'00000002(2): 2
C3
0010
Communications parity H'00000000(0): None
H'00000001(1): Even
H'00000002(2): Odd
C3
0011
Use SVĆbank
H'00000000(0): OFF
H'00000001(1): ON
Advanced
function setting
C3
0012
Use totalizing counter
H'00000000(0): OFF
H'00000001(1): ON
C3
0013
Display autoĆreturn
time
H'00000000(0): OFF
H'00000001 to H'00000063 (1 to 99)
C3
0014
MoveĆtoĆprotectĆlevel
time
H'00000003 to H'0000001E (3 to 30)
* 1: Communications parameters are enabled after they have been changed by turning the power OFF then back ON again.