Common to All Timers
H3DS-
@LC
B-45
Ti
m
e
rs
Installation of Screw-Less Clamp Models
■
Tools
A flat-blade screwdriver should be used to mount the cables.
Applicable Screwdriver
●
Flat-blade, Parallel-tip, 2.5 mm diameter
Examples: FACOM AEF.2.5
×
75E
VESSEL No. 9900-(-)2.5
×
75
WAGO 210-119
WIHA 260/2.5
×
40
■
Applicable Wires
Applicable Wire Sizes
0.2 to 1.5 mm
2
, AWG24 to AWG16
Applicable Wire Type
Solid wires, stranded wires, flexible wires, or wires with ferules can
be used.
(See note 1) < 1.8
≤
Diameter D (mm)
≤
3.0 (see note 2)
Conductor diameter d (mm) or length of sides a and b (mm)
≤
1.6
Note: 1.
If the overall diameter of the wire is less than 1.8 mm, do not
insert the wire past the conductor. Refer to the following di-
agrams.
2.
If the overall diameter of the wire is over 2.8 mm, it will be
difficult to use double wiring.
•
Flat-blade, Parallel-tip
•
Flat-blade, Flared-tip
Cannot be used.
2.5 dia.
Wires with Ferules
OK
NG