When using an all-in-one camera, specify whether to use data inside the
camera as 3D coordinate setting parameters.
Table: 3D Setting - 3D Coordinates (3D Camera Image Input)
Item
Set Value
[Factory
Default]
Description
The data camera has
When using an all-in-one camera, specify
whether to use data inside the camera as 3D
coordinate setting parameters.
[Checked]
The data inside the camera is used as 3D
coordinate setting parameters.
Availableness
Unchecked
The newly obtained data is used as 3D coordinate
setting parameters.
4. Set the "Optical condition setting" and "Sampling condition" as necessary.
Table: 3D Setting - 3D Coordinates (3D Camera Image Input)
Item
Set Value
[Factory Default]
Description
Focal length of
lens
1.0 to 999.9
[16.0]
Set the focal length of the
camera lens.
Optical
condition
setting
Photographing
ring
[0.0] to 999.9
Set the photographing ring of
the camera.
Sampling
condition
Sampling point
o
5 x
5
o
7 x
7
o
9 x
9
o
11 x
11
o
[7 x
Select the number of
sampling points for sampling
measurement. Unit is n points
x n points.
Set up [3D coordinates] in
the whole field of view.
The correspondence between
the field of view and
sampling points are shown
Содержание FZ2 Series
Страница 1: ...Cat No Z275 E1 01 FZ2 Series Vision Sensors USER S MANUAL...
Страница 6: ...Operation Flow Here describes the operation flow...
Страница 19: ...Input Operation This section describes the basic operations of input devices of this product...
Страница 23: ...The numerical value is input 3 Tap OK Verify the value and close the numeric keyboard...
Страница 51: ...6 Tap OK when drawing is over The settings are registered...
Страница 61: ...Example When judging the type and classifying measurement conditions according to images branch processing...
Страница 62: ......
Страница 64: ...Verifying Items This product can operate with a single controller or is connected to external devices...
Страница 66: ......
Страница 88: ...A new processing unit is inserted above the tapped unit and the number of the units below is incremented by one...
Страница 90: ...The Rename Unit window closes and the processing unit is renamed...
Страница 97: ...3 Tap OK The scene switches...
Страница 100: ...Locating Measurement Objects Not Inclined...
Страница 101: ......
Страница 102: ...Locating Measurement Objects Inclined Internal and External Measurement...
Страница 103: ...Presence Measurement...
Страница 104: ...Dimension Measurement Measurement...
Страница 105: ...Burr Measurement Text Comparison Measurement Defects Measurement...
Страница 106: ...Quantity Measurement Measurement Mixing Measurement...
Страница 107: ...Measuring Height 3D Measuring Position of Holes 3D...
Страница 108: ......
Страница 123: ......
Страница 138: ...The data copied from the source scene is written over the scene selected as the destination 5 Tap Close...
Страница 140: ...Scene data is deleted 5 Tap Close...
Страница 145: ...The data copied from the source scene group is written over the scene group selected as the destination 6 Tap Close...
Страница 147: ...4 Tap Yes Scene group data is deleted 5 Tap Close...
Страница 155: ...7 Tap Measure in the Toolbar on the Main screen The measurement on the selected image is performed...
Страница 168: ......
Страница 197: ...Analyzing Measured Data with PC This section describes how to analyze the measured data with PC...
Страница 203: ......
Страница 214: ...6 Tap OK The window to show the status of transfer is displayed and the data is sent to the destination...
Страница 216: ...5 Tap OK The window to show the status of transfer is displayed and the data is sent to the destination...
Страница 225: ...Communication Processing Flow Ethernet Connection The procedure to connect Ethernet Example Input measurement command...
Страница 264: ...Input measurement trigger with in STEP signal range Example When setting 2 for Number of delay Note...
Страница 329: ...value 0 000 Field of view Calculated value 640 This is an actual dimension in the X direction...
Страница 369: ...F Calculated value 0 000 Sight Calculated value 640 This is an actual dimension in the X direction...
Страница 410: ...limit Lower limit 0 to 255 vividness This can only be set when Fine is selected...
Страница 416: ...For the following operations see Setting up Color Data...
Страница 423: ...Region Setting Color Data...
Страница 426: ...133 Lower limit for density deviation for monochrome cameras only Set Get 0 to 127...
Страница 461: ...For the following operations see Setting up Flexible Search...
Страница 475: ...For the following operations see Setting up Edge Position...
Страница 494: ...For the following operations see Setting up Edge pitch...
Страница 509: ...Please verify the sequent operations by following Setting up Defect...
Страница 524: ...For the subsequent operations see Setting up Fine matching...
Страница 568: ...For the subsequent operations see Setting up Gravity and Area...
Страница 572: ...For the following operations see Setting up Gravity and Area...
Страница 588: ......
Страница 592: ...For the following operations please refer to Setting up Labeling...
Страница 640: ...For the subsequent operations see Setting up Character Inspection...
Страница 648: ...Reduce the measurement region size in Region Setting Region Setting Character Inspection...
Страница 688: ...edge For the subsequent operations see Setting Up Scan Edge Position...
Страница 716: ...specified edge color is detected as the edge For the subsequent operations see Setting Up Scan Edge Width...
Страница 895: ...Chapter 5 Branch Control This chapter describes how to set up branch processing Conditional Branch DI Branch End...
Страница 960: ...color R 157 Background color G Set Get 0 to 255 158 Background color B Set Get 0 to 255...