2-1. Position Control Unit Setup
Set the Position Control Unit number and servo drive station address.
Set the Position Control Unit number to 0.
LED Display
Shows status of Position Control Unit.
Name of Parts
CJ1W-NCF71
Unit Number Setup Switch
Sets the Position Control
Unit number (UNIT No.).
MECHATROLINK-II
Communication Connector
* Unit Number (UNIT No.) Setup Switch
Sets the Position Control Unit number (UNIT No.) as a CPU Bus unit.
Setup Range: 0 to F (Unit No.0 to Unit No.15)
Note: Factory setup is 0.
Based on the configured unit number, CPU Bus unit relay area is
assigned.
Position Control Unit uses the area as a relay area of common operation.
1875 to 1899
15
1575 to 1699
7
1850 to 1874
14
1650 to 1674
6
1825 to 1849
13
1625 to 1649
5
1800 to 1824
12
1600 to 1624
4
1775 to 1799
11
1575 to 1599
3
1750 to 1774
10
1550 to 1574
2
1725 to 1749
9
1525 to 1549
1
1700 to 1724
8
1500 to 1524
0
Channel
Assignment (CH)
Unit Number
Channel
Assignment (CH)
Unit Number
Caution: Before setting up the unit number, you must turn off the power.
Setting station address of the servo driver
Mount MECHATROLINK-II I/F units to servo drivers.
Set their addresses to “1”, “2”, and “3”.
2-2. Servo Driver Setup
* Servo Driver (W Series)
W series servo driver requires MECHATROLINK-
Ⅱ
I/F unit JUSP-NS115
(Yaskawa Electric). The following product versions are available.
You can find a version number on the side label.
W Series Servo Driver: Ver.39 or later
I/F Unit: VER.***03 or later
Remarks W series servo driver and I/F unit cannot operate normally if any
of them is older product version than the above. Use the appropriate
product version as shown above.
(1) Remove the connector
cover on the W series
driver’s option connector
(CN10).
(2) Attach NS115.
(3) For grounding, connect
NS115’s ground cable
using a screw on a part
marked as “G”.
Attaching I/F Unit NS115
Use SW1 and SW2 to configure MECHATROLINK communication
setting.
Do not change other bits of SW2 than bit 3 from factory shipment
settings.
* Station Number Setting
Use rotary switch (SW1) and piano switch (SW2-3) to configure the
settings as shown in the following table. SW2-3 is 10H digit and
SW1 is the lower digit.
Do not change the setting while the unit is turned on.
2-3 Position Control Unit
CJ1W-NCF71
16 to 30 (10H to 1EH)
0 to F
ON
1 to 15 (01H to 0FH)
1 to F
0: Do not set up
0
OFF
Station Number
SW1
SW2-bit3
Содержание FB LIBRARY -
Страница 1: ......
Страница 14: ...2 1 Controller Link Unit CJ1W CLK21 V1...
Страница 23: ...2 2 DeviceNet Slave DRT2 Series DRT2...
Страница 31: ...2 3 Position Control Unit CJ1W NCF71...
Страница 42: ...2 4 Position Control Unit CJ1W NC113 133 213 233 413 433...
Страница 49: ...2 5 Position Control Unit CS1W NC113 133 213 233 413 433...
Страница 57: ...2 6 Inverter 3G3MV A2 AB A4 3G3RV A2 A4...
Страница 71: ...2 7 Servo Driver R88D WT WT H WT HL R7D AP H AP L...
Страница 84: ...2 8 RFID ID Sensor V600 H...
Страница 95: ...2 9 Vision Sensor F160 C10...
Страница 105: ...2 10 2D Code Reader V530 R2000 R160 R150V3...
Страница 118: ...2 11 Smart Sensor ZX SF11 ZX LD40 ZX LDA11 N...
Страница 129: ...2 12 Temperature Controller E5ZN 2...
Страница 139: ...2 13 Temperature Control Unit CJ1W TC001 101 003 103 002 102 004 104...
Страница 148: ...Chapter 3 OMRON FB Library List Folder Configuration of The OMRON FB Library List of The OMRON FB Library...
Страница 162: ...Cat No R123 E01 01 Note Specifications subject to change without notice Printed in Japan Authorized Distributor...