F3SP-U5P-TGR
User's manual
6
2 GENERAL INFORMATION AND MAIN APPLICATIONS.
The single beam safety control unit F3SP-U5P-TGR has been designed and
produced to meet the need to protect persons in areas where it is necessary
to guarantee the safety of the operator using machinery, robots or in general
automation systems which are considered dangerous or subject to casual or
undesired access to unsafe parts.
The system conforms with the requirements for safety devices of type 4 in
compliance with international standards, e.g. IEC 61496 1-2.
WARNING
The safety system category depends on the safety PES’s used as follows.
Type 4 safety PES
: Safety system category 4
Type 2 safety PES
: Safety system category 2
•
A qualified person, as determined by local regulations, must confirm that
installation, inspection, and maintenance are implemented correctly.
•
Do not disassemble, repair, and modify the control unit and safety PES.
The control unit does not contain parts subject to maintenance.
•
The presence of a limb or an object interrupting one of the safety PESs
will open the safety outputs and consequently stop the connected
machine. It is necessary to install the safety PESs in such a way that
bypassing and defeating of any person is not possible.
•
Do not use the control unit and safety PES on machines that cannot be
stopped by electrical control in case of an emergency.
•
Do not use the control unit and safety PES in environments exposed to
flammable or explosive gases.
•
Do not use the control unit and safety PES in a retro-reflective
configuration. Otherwise detection may fail.
NOTICE
•
Do not install the control unit and safety PES in the following environments;
- Areas exposed to intense interference light such as direct sunlight.
- Areas with high-humidity where condensation is likely to occur.
- Areas exposed to corrosive gases.
- Areas exposed to vibration or shock levels higher than specification
provisions.
•
Do not use the cellular phones or transceivers near the control unit and
safety PES.
Содержание F3SP-U5P
Страница 3: ......
Страница 13: ...F3SP U5P TGR User s manual 12 BREAK GUARD FTC 4 FTC 3 FTC 2 FTC 1 5 2 PINOUT TOP VIEW ...
Страница 30: ...F3SP U5P TGR User s manual 29 13 OVERALL DIMENSIONS Control unit F3SP U5P TGR ...
Страница 31: ...F3SP U5P TGR User s manual 30 14 NOTE ...
Страница 32: ......