F3SP-U5P-TGR
User's manual
25
8 LED
DIAGNOSTIC
Information of the units operative state by means of four LEDs.
The LED state has the following meaning:
•
GREEN LEDs: if switched on, the photocells work regularly and no
object is detected; the relays are closed.
•
RED LED / GREEN LED: if switched on in RED, the unit has detected
an object or an error has occurred - which can be possibly recovered
by pressing the reset button -; in this condition, the safety outputs are
opened.
•
RED LED / GREEN LED: if switched on in GREEN, the barrier is
working regularly and there are no detected obstacles; in this condition,
the safety outputs are closed.
The Unit include a simple diagnostic indications on the most significant
errors.
-
One LED flashing.
Error in an photocell pair.
-
Two LED flashing.
Error in connection of bypassed PES.
-
Three LED flashing.
Error in muting lamp or invalid sequence of muting.
-
Four LED flashing.
Internal fail of system.
All these errors are resettable by the TEST pushbutton if the error condition
can be removed.
T
HE LED INDICATIONS CAN BE POSSIBLE ONLY IF THE SLC ASSOCIATED TO THE LED
FLASHING ARE FREE
.