F3SP-U5P-TGR
User's manual
28
12 TECHNICAL DATA.
•
Voltage: 24 Vdc
±
10%
•
Electrical input: 420 mA max (for any model)
•
Combinable photocells: OMRON E3FS series and
Techno GR S5 – S10 – S30 series
•
Number of photocells: four pairs max
•
Wire range: size AWG 14 – 24 Solid/Stranded
•
Wire type: 60/75 °C copper (Cu) conductor only
•
Torque on terminals: 2.0 N*m
•
Indicators: 4 green LEDs, 1 green/red LED
•
Response time:
≤
30 ms
•
Working temperature: -10 a + 55 °C
•
Humidity: from 15% to 95% (not condensing)
•
Output contacts: 2 NO, 250 Vac 2.5 A max
•
Switch capability: 1,500 VA, 180W
•
Electrical life expectance: 100.000 op. minimun at 1,800 oprs/hr.
•
Operative distance: according to the type of photocell
E3FS 10m
S5-5
8m
S5-10 8m
S30-5 50m
•
Outer
controls:
start/restart
control,
test
,
muting
•
Housing: plastic case for installation on a din/omega rail
•
Protection class of control unit: IP 20
•
Protection class of photocells: IP 67
•
Protection class of the cabinet containig the control-unit: IP54 at least
•
Weight: control unit 600 g
•
Features of fuses
muting
signalling lamp: internal resettable fuse
315mA T 60V
•
Muting
signalling: F39-A11
Содержание F3SP-U5P
Страница 3: ......
Страница 13: ...F3SP U5P TGR User s manual 12 BREAK GUARD FTC 4 FTC 3 FTC 2 FTC 1 5 2 PINOUT TOP VIEW ...
Страница 30: ...F3SP U5P TGR User s manual 29 13 OVERALL DIMENSIONS Control unit F3SP U5P TGR ...
Страница 31: ...F3SP U5P TGR User s manual 30 14 NOTE ...
Страница 32: ......