7 OPERATING
PROCEDURES.
7.1 DIP-SWITCHES
CONFIGURATION.
The configuration indicated in the table must be selected on both the
dip
-
switches
available in the front cover.
1
Function
X not
used
2
Function
Off
muting A-B act on the sensor couples 1
and 2.
muting C-D act on the sensor couples 3
and 4.
On
muting A-B act on the sensor couple 1.
muting C-D act on the sensor couple 2.
The sensor couples 3-4 continue to
function normally.
3
function
4
function
Off
muting 60 s
Off
manual restoring
On
muting
∞
s *
On
automatic
restoring
The control-unit is manufactured from the factory with the following configuration:
•
Automatic reset, all four sensors in
muting
, the maximum duration
of the
muting
is of sixty seconds.
* infinite muting duration: this feature must be used carefully because it’s
against the norm. Using this, the user must know that it works under its sole
responsibility.
7.2
CONFIGURATION OF THE NUMBER OF PHOTOCELLS.
In case you use a number of photocells which is lower than 4, operate as
follows: to disconnect the photocells do not use and therefore do not connect
to the control unit; carry out a connection among the following terminals:
unused photocell
connection
1
19 to 27
2
20 to 28
3
23 to 31
4
24 to 32
At least one pair of photocells must be connected, otherwise (condition of all
the disconnected photocells) the control unit is locked.
1
2
3
4
ON
4
3
2
1
ON
SW 2
SW 1