1-1
Section
Installation Precautions
3
Do not install the Controller in the orientations shown in the fol-
lowing diagram.
INCORRECT
Ambient Temperature
1
Maintain a minimum clearance of 50 mm above and below
F150 components to improve air circulation.
2
Do not install F150 components immediately above strong
heat sources, such as heaters, transformers, or large-ca-
pacity resistors.
3
Do not let the ambient operating temperature exceed 50
°
C.
4
Provide a forced-air fan or air conditioning if the ambient
temperature might exceed 50
°
C.
Control box
Louver
Noise Resistance
Use the following measures to help increase noise resistance.
1
Do not install F150 components in a cabinet containing
high-voltage equipment.