2-4
Section
CCTV Lens
13
2. If the field of vision is too small, use the F150-S1A Camera
with a normal CCTV lens and light.
→
p. 17
2-4
Power Supply and Ground
Wire the power supply and the ground to the top terminal block,
and tighten the screws to a torque of between 0.5 and 0.6 N
⋅
m.
After wiring, confirm that wiring and screw tightening have been
done properly.
Caution
Cover the terminal blocks with the Terminal Block Protection
Covers.
2-4-1
Crimp Terminals and Cables
The terminal block uses M3 terminal screws. Use appropriate
crimp terminals for M3 screws, as shown below.
Forked
Round
6.2 mm max.
6.2 mm max.
Applicable wire size:
Insulated wire of 1.31 to 1.65 mm
2
(AWG16 to AWG15)
2-4-2
Protective Conductor (Earth) Wiring
Wire the ground as shown in the following diagram.
Caution
Use an appropriate ground. An insufficient ground can affect
F150 operation or result in damage to F150 components.
•
To avoid damage to the equipment, do not share the protective
conductor wiring with any other devices nor wire the protective
conductor terminal to the girder. Be sure to wire the protective
conductor of the equipment independently.
•
Keep the ground line as short as possible.
Class I
(with protective conductor
terminal)
Содержание F150-2
Страница 1: ...Cat No Z132 E1 02 Manual 1 SETUP MANUAL F150 2 Vision Sensor...
Страница 2: ......
Страница 3: ...F150 2 Vision Sensor Setup Manual Revised May 2004...
Страница 4: ...vi...
Страница 10: ......
Страница 14: ......
Страница 20: ......
Страница 72: ......
Страница 84: ......
Страница 86: ......
Страница 87: ......
Страница 88: ...Z132 E1 02...