6 E3NW-CCL Function Specifications
6 - 12
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
Priority
Error
type
Description
Meaning
Solution
Response
from Sensor
Amplifier
Unit
Judged at
Communications
Unit
Low
High
00
No error
Initial status
---
OK
OK
0×01
Communicat
ions Error
Checksum error, timeout error, etc.
•
Retry.
•
Check
communications
with the Sensor
Unit.
OK
OK
0×02
Set Value
Error
Invalid command data value (e.g.,
out of range)
•
Tuning failed.
•
Hysteresis width data is out of
range.
•
Timer data is out of range.
Set the correct
data.
OK
---
0×04
Status Error
The Sensor Amplifier is currently not
in a state that can accept the
command.
•
Command was received in Setting
Mode.
•
A command for the second point
for two-point tuning was received,
but not for the first point.
•
A command for the second point
for positioning tuning was received,
but not for the first point.
Send the
commands at the
correct time.
OK
---
0×08
Command
Error
An unsupported command was sent
to the Sensor Amplifier Unit.
•
A command that could not be
executed was sent.
•
A channel that does not exist was
specified.
•
A read command was executed at
the same time for more than one
Sensor.
Set the correct
command.
OK
---
0×10
TRG Error
TRG was turned OFF before
processing was finished.
Keep TRG ON until
processing is
finished.
---
OK
Содержание E3NW-CCL
Страница 1: ...E3NW CCL CC Link Digital Sensor Communications Unit User s Manual Cat No E431 E1 08 ...
Страница 46: ...4 Mounting and Wiring 4 10 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 72: ...6 E3NW CCL Function Specifications 6 18 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 114: ...A Appendices A 34 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 116: ...B B 2 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 117: ......