3 Basic Application Procedures
3 - 8
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
4-2. Set the parameters.
(1) Set the Number of Modules to 1.
(2) Set the Start I/O No. .
(3) Set the mode for the operating mode you want to use.
To use Reduced I/O Mode, set the mode to Remote Network Version 1 Mode.
To use Monitor Mode, set the mode to Remote Network Version 2 Mode.
4-3. Select the
Set station information
in the CC-Link Configuration Window
Check Box, and
then select
CC-Link Configuration Settings
.
5
Set the CC-Link configuration.
5-1. Select the settings based on your CC-Link system configuration.
You can select and drag Units from the Unit List to make the settings.
5-2. Set the following settings based on the baud rate and operating mode settings for the
E3NW-CCL.
5-2-1. Match the conditions shown in the following locations (in GX-Works2 and the
E3NW-CCL setting switches).