5 - 5
5 E3NW-CCL Hardware Specifications
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
5-
3 Hardware Spe
cificat
ion
s
5
5-
3-1 S
tatus Indicato
rs
5-3
Hardware Specifications
These indicators show the current status of the E3NW-CCL.
This indicator shows the operating status.
This indicator displays errors.
This indicator compares the number of Sensor Units connected when power was turned ON to the
number of Sensor Units actually connected and indicates the Sensor connection status.
5-3-1
Status Indicators
RUN Indicator
Color
State
Description
Green
Not lit.
CC-Link communications are disconnected or the Unit is
being reset.
Lit.
CC-Link communications are in progress.
ERR Indicator
Color
State
Description
Red
Not lit.
Normal transmission
Flashing
The station setting switch or baud rate setting/operating
mode setting switch was changed during communications.
Lit.
Communications error or station number setting out of
range
SS Indicator
Color
State
Description
Not lit.
No Sensor Amplifier Units are connected or initialization is
being performed after the power supply was turned ON.
Green
Lit.
Normal: The number of connected Sensor Units when
power was turned ON matches the actual number of
connected Sensor Units
Red
Lit.
Error: The number of connected Sensor Units when power
was turned ON does not match the actual number of
connected Sensor Units
RUN
ERR
SS
Содержание E3NW-CCL
Страница 1: ...E3NW CCL CC Link Digital Sensor Communications Unit User s Manual Cat No E431 E1 08 ...
Страница 46: ...4 Mounting and Wiring 4 10 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 72: ...6 E3NW CCL Function Specifications 6 18 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 114: ...A Appendices A 34 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 116: ...B B 2 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 117: ......