A - 9
A Appendices
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
A-
1 Usin
g Co
mm
and
s fo
r C
o
m
m
un
icat
ions
A
0×6E
Percentage Tuning
Setting or Origin Point
Use Setting
FA
□
0, LA0, MA0, FAH0, or EA
□
0
0: Percentage tuning OFF
1: Percentage tuning ON
TA0
0: Origin point use setting ON
1: Origin point use setting OFF
FA
□
0
MA0
LA0
EA
□
0
-
-
TA0
-
FAH0
-
0×6F
Percentage Tuning Level
or Preset Value
FA
□
0, LA0, MA0, FAH0, or EA
□
0
−
99 to 99
TA0
−
19999999 to 99999999
FA
□
0
MA0
LA0
EA
□
0
-
-
TA0
-
FAH0
-
0×71
Power Tuning Setting,
Tolerance Setting High, or
Scaling Lower Limit
Setting
FA
□
0, LA0, MA0, or FAH0
0: Power tuning setting ON
1: Power tuning setting OFF
2: Power Tuning ON When Power
Turned On (FA
□
0 only)
TA0
−
1999999 to 9999999
AA
□
0 or VA
□
0
−
1999.9999 to 9999.9999
FA
□
0
MA0
LA0
-
-
AA
□
0
TA0
VA
□
0
FAH0
-
0×72
Power Tuning Level,
Tolerance Setting Low, or
Scaling Higher Limit
Setting
FA
□
0, LA0, MA0, or FAH0
100 to 9999
TA0
−
1999999 to 9999999
AA
□
0 or VA
□
0
−
1999.9999 to 9999.9999
FA
□
0
MA0
LA0
-
-
AA
□
0
TA0
VA
□
0
FAH0
-
0×7B
Background Suppression
0: Background suppression OFF
1: Background suppression ON
-
-
-
-
SA0
-
-
-
-
-
0x80
External input detection
time
You can change the time external
input is enabled.
5 to 9999 ms
-
-
-
-
-
-
-
-
-
VD
□
0
0x86
Response Data Change
AA
□
0 or VA
□
0
0: Read input measurement value that
is input. (Before scaling and zero reset)
1: Read displayed measurement value.
(After scaling and zero reset)
-
-
-
-
-
AA
□
0
-
VA
□
0
-
-
0×91
Direction Selection
0: Normal
1: Reversed
-
-
-
-
-
-
TA0
-
-
-
0×92
Output Selection
Gain switching
TA
0: Normal
1: Hybrid
VD
0: Gain x4000
1: Gain x2000
2: Gain x800
3: Gain x200
4: Gain x80
5: Gain x20
6: Gain x4
7: Gain x1
-
-
-
-
-
-
TA0
-
-
VD
□
0
0×95
Preset
0: Cleared
1: Executed
-
-
-
-
-
-
TA0
-
-
* Commands to the E9NC-TA0 are supported from Ver. 1100, and E3NX-MA0, E2NC-EA
□
0, and E9NC-AA
□
0
/VA
□
0/VD
□
0 are supported from Version 1160.
You can check the version with read command "B". (Refer to page A-2)
Command
type
RWwn+2
Name
Read values
RWrm+2: Received Data 1 Area
RWrm+3: Received Data 2 Area
Applicable Sensor Amplifier Units
Содержание E3NW-CCL
Страница 1: ...E3NW CCL CC Link Digital Sensor Communications Unit User s Manual Cat No E431 E1 08 ...
Страница 46: ...4 Mounting and Wiring 4 10 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 72: ...6 E3NW CCL Function Specifications 6 18 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 114: ...A Appendices A 34 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 116: ...B B 2 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Страница 117: ......