4-2
Section
Programming Console Operations
112
At this point, the contents of the displayed word can be changed with a
signed-decimal input. Refer to
4-2-24 Signed Decimal Data Modification
.
3. Press the CLR Key or the SHIFT+TR Keys to end the unsigned decimal dis-
play and return to normal monitoring.
CLR
c200 cL0020000
FFF0 0000^ OFF
4-2-19 Unsigned Decimal Monitor
This operation is used to convert hexadecimal data in a word to unsigned
decimal for display. The operation can be executed while using I/O monitor-
ing, multiple address monitoring or 3-word monitoring.
RUN
MONITOR
PROGRAM
OK
OK
OK
1, 2, 3...
1. Monitor the word that is to be used for decimal monitor without sign. During
multiple address monitoring, the leftmost word will be converted.
Multiple address monitoring
c200 cL0020000
FFF0 0000^ OFF
2. Press the SHIFT+TR+NOT Keys to display the leftmost word as unsigned
decimal.
SHIFT
TR
NOT
c200
65520
At this point, the contents of the displayed word can be changed with an un-
signed-decimal input. Refer to
4-2-25 Unsigned Decimal Data Modification
.
3. Press the CLR Key or the SHIFT+TR Keys to end the unsigned decimal dis-
play and return to normal monitoring.
CLR
c200 cL0020000
FFF0 0000^ OFF
4-2-20 Three-Word Data Modification
This operation is used to change the contents of one or more of the 3 con-
secutive words displayed in the Three-Word Monitor operation. It is possible
in MONITOR or PROGRAM mode only.
RUN
MONITOR
PROGRAM
No
OK
OK
Caution
Before changing the contents of I/O memory, be sure that the changes will not
cause equipment to operate unexpectedly or dangerously. In particular, take
care when changing the status of output bits. The PC continues to refresh I/O
bits even if the PC is in PROGRAM mode, so devices connected to output points
on the CPU Unit, Expansion Units, or Expansion I/O Units may operate unex-
pectedly.
1, 2, 3...
1. Monitor the status of the desired words according to the procedure de-
scribed
4-2-17 Three-Word Monitor
.
(Three-word monitor)
D0002D0001D0000
0123 4567 89AB
Содержание CPM2A - 11-2005
Страница 1: ...OPERATION MANUAL Programmable Controllers SYSMAC CPM2A Cat No W352 E1 07...
Страница 2: ...CPM2A Programmable Controllers Operation Manual Revised November 2005...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 12: ...xiv...
Страница 179: ...Appendix B Dimensions 164 CPM1 CIF11 RS 422 Adapter...