419
3Z4L Laser Micrometer Protocol
Appendix K
Deflection Measurement Start (4000-series) (Sequence No. 435
(Hex 01B3))
This sequence starts a deflection measurement.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note 1.
The deflection measurement keeps measuring until sequence No. 438 (Measurement Termination)
is executed.
2.
This sequence will be processed the same as sequence No. 411 Zero run measurement start for
5000-series Laser Micrometers.
Continuous Measurement Start (Scan) (4000-series)
(Sequence No. 436 (Hex 01B4))
This sequence starts a continuous measurement. The scan notification method is used for the receive data.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
The receive data word allocation is similar to that of sequence No. 434 (Single Run Measurement Start).
Note 1.
Since this sequence repeats itself within the sequence, once it is executed, it remains in the execution
state until cancelled.
2.
Even if execution is cancelled, the Laser Micrometer still keeps measuring. Execute sequence No.
438 (Measurement Termination) to end the sequence.
Continuous Measurement Start (Interrupt) (4000-series)
(Sequence No. 437 (Hex 01B5))
This sequence starts a continuous measurement. The interrupt notification method is used for the receive data
and the interrupt No. is 101.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Offset
Contents (data format)
Data
+0
Number of receive data
words (4 digits Hex)
With no reference setting: 0005
With reference setting: 0008
+1
Decision result
(ASCII 2 characters)
With no limit setting: 0000
With limit setting: 2B4E (“+N”), 4F4B (“OK”), 2D4E (“–
N”)
+2
Measurement value (decimal
portion)
(4 digits BCD)
0000 to 9999
+3
Measurement value (integer
portion)
(3 digits BCD)
000 to 999
+4
Measurement value (Sign)
(BIN)
If +: 0
If –: F
+5 to +7 Deviation value
Same as measurement value
*The deviation will be stored in this area only when ref-
erence setting is made.
4 5 6 7
0 1 2 3
F 0 0 0
+2
+3
+4
Example
–123.4567
Содержание CJ1W-SCU41
Страница 2: ...6 60 6 6HULHV 6HULDO RPPXQLFDWLRQV RDUGV DQG 6HULDO RPPXQLFDWLRQV 8QLWV 2SHUDWLRQ 0DQXDO 5HYLVHG 0D ...
Страница 3: ...KX ...
Страница 5: ...XK ...
Страница 9: ......
Страница 19: ......
Страница 119: ......
Страница 177: ......
Страница 187: ......
Страница 221: ......
Страница 259: ......
Страница 317: ......
Страница 333: ......
Страница 373: ......
Страница 395: ......
Страница 407: ......
Страница 443: ......
Страница 463: ......
Страница 501: ......
Страница 509: ......
Страница 513: ......
Страница 525: ......
Страница 526: ... XWKRUL HG LVWULEXWRU Cat No W336 E1 3 Note Specifications subject to change without notice Printed in Japan 0501 M ...